An Analytical Model of NPS and DQE Comparing Photon Counting and Energy Integrating Detectors
Raymond J Acciavatti1, Andrew D A Maidment1
1University of Pennsylvania, Department of Radiology, 3400 Spruce St., Philadelphia PA 19104.
Abstract:
In this work, analytical models of the optical transfer function (OTF), noise power spectra (NPS), and detective quantum efficiency (DQE) are developed for two types of digital x-ray detectors. The two detector types are (1) energy integrating (EI), for which the point spread function (PSF) is interpreted as a weighting function for counting x-rays, and (2) photon counting (PC), for which the PSF is treated as a probability. The OTF is the Fourier transform of the PSF. The two detector types, having the same PSF, possess an equivalent OTF. NPS is the discrete space Fourier transform (DSFT) of the autocovariance of signal intensity. From first principles, it is shown that while covariance is equivalent for both detector types, variance is not. As a consequence, provided the two detector types have equivalent PSFs, a difference in NPS exists such that NPSPC ≥ NPSEI and hence DQEPC ≤ DQEEI. The necessary and sufficient condition for equality is that the PSF is either zero or unity everywhere. A PSF modeled as the convolution of a Lorentzian with a rect function is analyzed in order to illustrate the differences in NPS and DQE. The Lorentzian models the blurring of the x-ray converter, while the rect function reflects the sampling of the detector. The NPS difference between the two detector types is shown to increase with increasing PSF width. In conclusion, this work develops analytical models of OTF, NPS, and DQE for energy integrating and photon counting digital x-ray detectors.
More Related Videos
08:48High-Resolution Neutron Spectroscopy to Study Picosecond-Nanosecond Dynamics of Proteins and Hydration Water
Published on: April 28, 2022
11:27Studying Soft-matter and Biological Systems over a Wide Length-scale from Nanometer and Micrometer Sizes at the Small-angle Neutron Diffractometer KWS-2
Published on: December 8, 2016
Related Concept Videos
Atomic Emission Spectroscopy: Overview
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
Mass Analyzers: Common Types
Atomic Emission Spectroscopy: Instrumentation