Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

A near X-point charge exchange neutral spectroscopy (CENS) system for DIII-D.

The Review of scientific instruments·2024
Same author

Calibration improvements expand filterscope diagnostic use.

The Review of scientific instruments·2024
See all related articles

Related Experiment Video

Updated: Jun 18, 2025

Quantitatively Measuring In situ Flows using a Self-Contained Underwater Velocimetry Apparatus SCUVA
09:22

Quantitatively Measuring In situ Flows using a Self-Contained Underwater Velocimetry Apparatus SCUVA

Published on: October 31, 2011

13.0K

Identifying divertor detachment using a machine learning model trained on divertor camera images from DIII-D.

B S Victor1, F Scotti1

  • 1Lawrence Livermore National Laboratory, Livermore, California 94550, USA.

The Review of Scientific Instruments
|August 1, 2024
PubMed
Summary

A machine learning algorithm accurately detects plasma divertor detachment in DIII-D fusion energy experiments using CIII imaging. This rapid assessment aids operational control and could be extended to other fusion devices.

More Related Videos

Quantitative Visualization and Detection of Skin Cancer Using Dynamic Thermal Imaging
06:08

Quantitative Visualization and Detection of Skin Cancer Using Dynamic Thermal Imaging

Published on: May 5, 2011

16.8K
Author Spotlight: Enhancing PSC-to-Functional Cell Differentiation Using ML Models Based on Live-Cell Bright-Field Imaging
11:38

Author Spotlight: Enhancing PSC-to-Functional Cell Differentiation Using ML Models Based on Live-Cell Bright-Field Imaging

Published on: October 4, 2024

532

Related Experiment Videos

Last Updated: Jun 18, 2025

Quantitatively Measuring In situ Flows using a Self-Contained Underwater Velocimetry Apparatus SCUVA
09:22

Quantitatively Measuring In situ Flows using a Self-Contained Underwater Velocimetry Apparatus SCUVA

Published on: October 31, 2011

13.0K
Quantitative Visualization and Detection of Skin Cancer Using Dynamic Thermal Imaging
06:08

Quantitative Visualization and Detection of Skin Cancer Using Dynamic Thermal Imaging

Published on: May 5, 2011

16.8K
Author Spotlight: Enhancing PSC-to-Functional Cell Differentiation Using ML Models Based on Live-Cell Bright-Field Imaging
11:38

Author Spotlight: Enhancing PSC-to-Functional Cell Differentiation Using ML Models Based on Live-Cell Bright-Field Imaging

Published on: October 4, 2024

532

Area of Science:

  • Fusion energy research
  • Plasma physics
  • Machine learning applications

Background:

  • Divertor detachment is a critical plasma physics phenomenon in tokamak fusion devices like DIII-D.
  • Accurate and timely detection of divertor detachment is essential for maintaining stable plasma conditions and device protection.
  • Current methods for detachment detection may not provide the rapid assessment needed for real-time operational control.

Purpose of the Study:

  • To apply a convolutional neural network (CNN) based machine learning (ML) algorithm for automated detection of divertor detachment in DIII-D.
  • To evaluate the accuracy and effectiveness of the ML model in identifying detached plasma conditions from CIII emission imaging.
  • To establish a rapid assessment tool for divertor detachment to support DIII-D operations.

Main Methods:

  • Utilized a CNN ML algorithm, previously developed by Boyer et al., for image analysis.
  • Trained and tested the ML model on CIII emission images (465 nm) from upper and lower filtered divertor cameras in DIII-D.
  • Developed separate ML models for lower single null (LSN) and upper single null (USN) plasma configurations with closed divertor shapes.

Main Results:

  • The ML model achieved 100% accuracy in detecting divertor detachment from upper divertor images due to stark CIII emission contrast.
  • The ML model achieved 96% accuracy in detecting detachment from lower divertor images, where the CIII emission contrast is less pronounced.
  • The developed models demonstrated high performance in classifying attached versus detached plasma conditions.

Conclusions:

  • The ML algorithm effectively detects divertor detachment in DIII-D using CIII imaging, with high accuracy for both upper and lower divertor configurations.
  • This automated detection provides a rapid assessment crucial for real-time operational feedback in DIII-D.
  • The methodology shows potential for extension to other fusion devices, enhancing operational capabilities and plasma control.