Related Experiment Video
Updated: Jun 18, 2025

Evaluation of Capnography Sampling Line Compatibility and Accuracy when Used with a Portable Capnography Monitor
Published on: September 29, 2020
Continuous Capnography for Early Detection of Respiratory Compromise During Gastroenterological Procedural Sedation
1Stacey C. Tobin, PhD, is a Senior Medical Writer at The Tobin Touch, Inc., Arlington Heights, Illinois.
Abstract:
Gastroenterology nurses working across a variety of clinical settings are responsible for periprocedural monitoring during moderate to deep procedural sedation and analgesia (PSA) to identify signs of respiratory compromise and intervene to prevent cardiorespiratory events. Pulse oximetry is the standard of care for respiratory monitoring, but it may delay or fail to detect abnormal ventilation during PSA. Continuous capnography, which measures end-tidal CO2 as a marker of alveolar ventilation, has been endorsed by a number of clinical guidelines. Large clinical trials have demonstrated that the addition of continuous capnography to pulse oximetry during PSA for various gastroenterological procedures reduces the incidence of hypoxemia, severe hypoxemia, and apnea. Studies have shown that the cost of adding continuous capnography is offset by the reduction in adverse events and hospital length of stay. In the postanesthesia care unit, continuous capnography is being evaluated for monitoring opioid-induced respiratory depression and to guide artificial airway removal. Studies are also examining the utility of continuous capnography to predict the risk of opioid-induced respiratory depression among patients receiving opioids for primary analgesia. Continuous capnography monitoring has become an essential tool to detect early signs of respiratory compromise in patients receiving PSA during gastroenterological procedures. When combined with pulse oximetry, it can help reduce cardiorespiratory adverse events, improve patient outcomes and safety, and reduce health care costs.
More Related Videos
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Endoscopic Procedures IV: Sigmoidoscopy and Laproscopy
Sigmoidoscopy
Sigmoidoscopy is a diagnostic procedure that uses a flexible sigmoidoscope equipped with a light source and camera to examine the rectum and sigmoid colon. The procedure involves inserting the tube through the anus...
Acute Respiratory Failure-III
Endoscopic Procedures III: Video Capsule Endoscopy
Suctioning the Nasopharyngeal Airway
Equipment Required
Endoscopic Studies II: Thoracocentesis
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...