Related Experiment Video
Updated: May 2, 2026

MR Molecular Imaging of Prostate Cancer with a Small Molecular CLT1 Peptide Targeted Contrast Agent
Published on: September 3, 2013
Comparison of golden-angle radial sparse parallel (GRASP) and conventional cartesian sampling in 3D dynamic
Yoshiko Ueno1, Keitaro Sofue2, Tsutomu Tamada2,3
1Department of Radiology, Kobe University Graduate School of Medicine, 7-5-2, Kusunoki-Cho, Chuo-Ku, Kobe, Hyogo, 650-0017, Japan. yoshiu@med.kobe-u.ac.jp.
Purpose:
To compare the image quality, inter-reader agreement, and diagnostic capability for muscle-invasive bladder cancer (MIBC) of the reconstructed images in sections orthogonal to the bladder tumor obtained by 3D Dynamic contrast-enhanced (DCE)-MRI using the Golden-angle Radial Sparse Parallel (GRASP) technique with the images directly captured using the Cartesian sampling.
Materials And Methods:
This study involved 68 initial cases of bladder cancer examined with DCE-MRI (GRASP: n = 34, Cartesian: n = 34) at 3 Tesla. Four radiologists conducted qualitative evaluations (overall image quality, absence of motion artifact, absence of streak artifact, and tumor conspicuity) using a five-point Likert scale (5 = Excellent/None) and quantitative signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) measurements. The areas under the receiver-operating characteristic curves (AUCs) for the Vesical Imaging-Reporting and Data System (VI-RADS) DCE score for MIBC assessment were calculated. Inter-reader agreement was also assessed.
Results:
GRASP notably enhanced overall image quality (pooled score: GRASP 4 vs. Cartesian 3, P < 0.0001), tumor conspicuity (5 vs. 3, P < 0.05), SNR (Median 38.2 vs. 19.0, P < 0.0001), and CNR (7.9 vs. 6.0, P = 0.005), with fewer motion artifacts (5 vs. 3, P < 0.0001) and minor streak artifacts (5 vs. 5, P > 0.05). Although no significant differences were observed, the GRASP group tended to have higher AUCs for MIBC (pooled AUCs: 0.92 vs. 0.88) and showed a trend toward higher inter-reader agreement (pooled kappa-value: 0.70 vs. 0.63) compared to the Cartesian group.
Conclusions:
Using the GRASP for 3D DCE-MRI, the reconstructed images in sections orthogonal to the bladder tumor achieved higher image quality and improve the clinical work flow, compared to the images directly captured using the Cartesian. GRASP tended to have higher diagnostic ability for MIBC and showed a trend toward higher inter-reader agreement compared to the Cartesian.
Related Concept Videos
Imaging Studies I: Kidney, Ureter, and Bladder Studies
Imaging Studies III: Computed Tomography
Imaging Studies IV: Magnetic Resonance Imaging

