Related Experiment Video
Updated: Jun 18, 2025

A General Method for Detecting Nitrosamide Formation in the In Vitro Metabolism of Nitrosamines by Cytochrome P450s
Published on: September 25, 2017
A multianalyte LC-MS/MS method for accurate quantification of Nitrosamines in Olmesartan tablets
Namdev Pawar1, Aparna Bhardwaj1, Amisha Vora2
1Department of Chemistry, Mithibai College Of Arts, Chauhan Institute of Science & Amrutben Jivanlal College Of Commerce And Economics, Vile Parle West, Mumbai 400056, India.
Abstract:
This research summaries the development, optimization and validation of liquid chromatography tandem mass spectrometric (LC-MS/MS) method for concurrent measurement of seven nitrosamines viz; NDMA, NDEA, NDIPA, NDPA, NEIPA, NMPA & NMBA in Olmesartan tablet. Controlling these nitrosamines at trace levels is imperative for ensuring the safety of drug substances and products for consumption. Various regulatory authorities stress the significance of utilizing highly sensitive analytical methods to precisely measure nitrosamines at trace levels. The method applied effective chromatographic separation and optimized parameters for mass spectrometric detection. Detection was carried out using APCI positive ion mode. Chromatographic separation was achieved using a Thermo Accucore PFP column (150 mm x 4.6 mm, 2.6 µ), with a simple gradient elution of mobile phase consisting of 0.1 % formic acid in water (mobile phase A) and methanol (mobile phase B). The total run time was 20 min, with a flow rate of 0.800 mL/min. The method was validated according to the International Council on Harmonisation (ICH Q2 (R2)) guidelines. The established method demonstrated excellent linearity (R2> 0.99) and sensitivity for all the nitrosamines. Detection and quantification limits were sufficiently low for trace nitrosamine levels having good S/N ratio. The method showed good accuracy in Olmesartan tablet samples, with recoveries ranges between 80 % to 120 %. The new analytical approach has exceptional repeatability and reliability, making it possible to precisely quantify the levels of seven nitrosamines in Olmesartan medoxomil tablets in a single analytical run.
More Related Videos
08:41Integration of Miniaturized Solid Phase Extraction and LC-MS/MS Detection of 3-Nitrotyrosine in Human Urine for Clinical Applications
Published on: July 14, 2017
10:38Simultaneous Quantification of Selected Kynurenines Analyzed by Liquid Chromatography-Mass Spectrometry in Medium Collected from Cancer Cell Cultures
Published on: May 9, 2020