Background And Aims:
Transcatheter aortic valve replacement (TAVR) determined a paradigm shift in the treatment of patients with severe symptomatic aortic stenosis but data on very long-term durability are lacking. We sought to evaluate the clinical and hemodynamic outcomes of the CoreValve porcine pericardial self-expanding bioprosthesis at 12-year follow-up.
Methods:
882 inoperable or high-risk patients were treated with the CoreValve bioprosthesis in 8 Italian high-volume centers between 2007 and 2011. The endpoints were 12-year all-cause and cardiovascular mortality, and Cumulative Incidence Functions (CIFs) for severe Structural Valve Deterioration (SVD), Bioprosthetic Valve Dysfunction (BVD), Bioprosthetic Valve Failure (BVF), and severe Hemodynamic Valve Deterioration (HVD). VARC-3 definitions were applied.
Results:
Baseline characteristics included a mean age of 83 ± 6 years, and NYHA class III or IV in 76.3 % of patients. The actuarial risk of death at 12 years after TAVR was 95.5 % (CI 93.5 %- 97.1 %). The actual risk of cardiovascular death, weighted against the risk of non-cardiac death at 12 years was 23.9 % (21.0 %-26.8 %). The 12-year actual risk of BVD was 7.0 % (5.3 %-8.9 %), of SVD was 3.6 % (2.5 %-5.2 %), of BVF was 3.12 % (2.02 %-4.57 %), and of severe HVD was 1.7 % (0.9 %-2.9 %). Mean transaortic gradient significantly decreased after the procedure (52 ± 15 mmHg vs 9 ± 5 mmHg, p < 0.001), and remained stable up to 12 years (12 ± 4 mmHg, P = 0.08 vs. discharge).
Conclusions:
The first-generation CoreValve bioprosthesis showed reassuring clinical and hemodynamic performance at 12-year follow-up.
More Related Videos
05:31Transcatheter Pulmonary Valve Replacement from Autologous Pericardium with a Self-Expandable Nitinol Stent in an Adult Sheep Model
Published on: June 8, 2022
12:17Full-root Aortic Valve Replacement by Stentless Aortic Xenografts in Patients with Small Aortic Roots
Published on: May 21, 2017
Related Concept Videos
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...
Treatment for Pulmonary Arterial Hypertension: Prostacyclin Receptor Agonists
These agonists bind to the IPR receptor situated on the plasma membrane of the pulmonary artery smooth muscle cells. This binding triggers a cascade of reactions known as the GS-AC-cAMP-PKA pathway. This pathway results in the relaxation of smooth muscle...
Clinical Trials: Overview
Clinical Trials
There are four phases in a clinical trial. A phase one...
Treatment for Pulmonary Arterial Hypertension: Endothelin Receptor Antagonists
ETs are synthesized through a complex sequence of enzymatic steps, primarily involving an enzyme referred to as endothelin-converting enzyme...
Thoracic Aorta