Related Experiment Video
Updated: Jun 18, 2025

Kinematic History of a Salient-recess Junction Explored through a Combined Approach of Field Data and Analog Sandbox Modeling
Published on: August 5, 2016
Seismic response of mountain tunnel induced by fault slip
Chen Xia1,2, Zian Wang2, Yongsheng He3
1State Key Laboratory of Target Vulnerability Assessment, Institute of Defense Engineering, AMS, PLA, Beijing, China.
Abstract:
With the rapid development of Chinese transportation networks, such as the Sichuan-Tibet railway, numerous tunnels are under construction or planned in mountainous regions. Some of these tunnels must traverse or be situated near active fault zones, which could suffer damage from fault slip. In this study, the seismic response of a mountain tunnel subjected to coseismic faulting was analyzed using a fault-structure system in a two-step process. Firstly, a nonuniform slip model was proposed to calculate the ground deformations and internal displacements induced by a specific active fault on a geological scale, considering nonuniform slips on the fault plane. The 1989 Loma Prieta and 2022 Menyuan earthquakes were chosen as case studies to validate the proposed slip model. Secondly, the calculated displacement of the Menyuan earthquake was used as the input load for the discrete-continuous coupling analysis of the Daliang tunnel on an engineering scale. The simulated deformation of the Daliang tunnel aligned with the on-site damage observations following the Menyuan earthquake. Lastly, the effects of different fault conditions on the tunnel seismic response were investigated. The results indicate that the distribution of the peak longitudinal strain of the lining is governed by fault mechanisms, and the degree of fault slip significantly influences the response of the tunnel. A tunnel passing through an active fault with a wider fault fracture zone and smaller dip angle experience less damage.
Related Concept Videos
Upward Impending Motion
To better comprehend how a screw jack functions, consider the completely unraveled thread as a block in contact with the...
Slump Test
Concrete is poured into the mold in three layers to conduct the test. Each layer is compacted 25 times with a steel tamping rod, which has a five-eighths-inch diameter and a rounded end, to ensure even distribution and eliminate...
Thin-Walled Hollow Shafts
Types of Building Separation Joints
Volume-change joints address the effects of expansion and contraction due to temperature and moisture variations. They are strategically placed at discontinuities in a building's mass where cracking is most likely and are spaced about 150 to 200...
Stresses in a Shaft
Applying equilibrium conditions to the QR segment establishes that the internal shearing forces within the...
Effects of Creep