Related Experiment Video
Updated: Jun 18, 2025

A Coupled Experiment-finite Element Modeling Methodology for Assessing High Strain Rate Mechanical Response of Soft Biomaterials
Published on: May 18, 2015
The Effects of Using PEEK Copings and Different Restorative Materials on the Stress Distribution in
Purpose:
To evaluate the influence of using polyetheretherketone (PEEK) copings and/or three different dental restorative materials for the success of tooth-and-implant-supported fixed partial dentures (TISFPDs) in the maxillary posterior region under static loading via 3D finite element analysis (3D FEA).
Materials And Methods:
Six 3D FEA models were designed for the extraction of maxillary first and second molars. The following elements were modeled: bone, implant, abutment, PEEK copings, second premolar, periodontal ligament (PDL), and six three-unit TISFPDs with different restorative materials (porcelain-fused-to metal [PFM], PEEK-composite [PC], monolithic zirconia [MZ]). Then PEEK copings were modeled to be cemented onto the implants as a double-crown system for the first three groups (PFMPEEK, PCPEEK, and MZPEEK), whereas the next three groups (PFM, PC, and MZ) excluded a PEEK coping in their designs. The prostheses were loaded twice-once vertically and once obliquely. From the determined points, 250 N for vertical loading (0 degrees to the long axis) and 200 N for the oblique loading (30 degrees to the long axis) were applied. Von Mises stresses and maximum and minimum principal stress values were analyzed.
Results:
Regardless of the material used for the suprastructure, the maximum average stress was reduced by the use of PEEK copings. Considering the maximum stress distribution, PC appeared to have the highest stresses on the cortical bone, implant, and screw. Additionally, the von Mises stresses formed in the PDL model were lower when a PEEK coping was included in the design of the TISFPD, reducing the risk of intrusion.
Conclusions:
The stress distribution was positively affected by the PEEK coping in the TISFPD design, reducing bone resorption and failure. This elastic material generated lower stresses at the bone and implant, and no significant effect was found on stresses around natural teeth.
More Related Videos
07:42Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
07:09In situ Compressive Loading and Correlative Noninvasive Imaging of the Bone-periodontal Ligament-tooth Fibrous Joint
Published on: March 7, 2014
Related Concept Videos
Stress: General Loading Conditions
The shearing force, possessing potential directionality within the plane of the section, is simplified into two component forces running parallel to the x and y axes....
Residual Stresses in Bending
Stress Concentrations
Components of Stress
Interestingly, the hidden cube faces also experience these stresses, equal and...
Residual Stresses
Residual Stresses in Circular Shafts