Related Experiment Videos
Sensitive high performance liquid chromatographic analysis of ethmozin in plasma
Therapeutic Drug Monitoring
|January 1, 1985
Summary
This study details a sensitive high-performance liquid chromatography method for quantifying ethmozin. The method offers reliable detection and quantification of ethmozin in biological samples.
Area of Science:
- Analytical Chemistry
- Pharmacology
Background:
- Ethmozin is an antiarrhythmic drug requiring precise quantification.
- Accurate measurement of ethmozin is crucial for therapeutic drug monitoring and pharmacokinetic studies.
Purpose of the Study:
- To develop and validate a sensitive high-performance liquid chromatography (HPLC) method for the quantitative determination of ethmozin.
- To establish a reliable analytical procedure for ethmozin in biological matrices.
Main Methods:
- A one-step liquid-liquid extraction using diethylether at pH 9.0.
- Separation on a CN-bonded column with a methanol-propanol-2-perchloric acid mobile phase.
- Detection of ethmozin at 268 nm using HPLC.
Main Results:
- The developed HPLC method demonstrated high sensitivity.
- The lower limit of detection (LOD) was 11 nM, and the lower limit of quantification (LOQ) was 22 nM (10 ng/ml).
- The method exhibited linearity over a wide concentration range (0–8,620 nM).
Conclusions:
- A sensitive and reliable HPLC method for ethmozin quantification has been established.
- This method is suitable for accurate determination of ethmozin in relevant concentrations.