Abstract:
Seismocardiographic (SCG) signals are chest wall vibrations induced by cardiac activity and are potentially useful for cardiac monitoring and diagnosis. SCG waveform is observed to vary with respiration, but the mechanism of these changes is poorly understood as alterations in autonomic tone, lung volume, heart location and intrathoracic pressure are all varying during the respiratory cycle. Understanding SCG variability and its sources may help reduce variability and increase SCG clinical utility. This study investigated SCG variability during breath holding (BH) at two different lung volumes (i.e., end inspiration and end expiration) and five airway pressures (i.e., 0, ± 2-4, and ± 15-20 cm H2O). Variability during normal breathing was also studied with and without grouping SCG beats into two clusters of similar waveform morphologies (performed using the K-medoid algorithm in an unsupervised machine learning fashion). The study included 15 healthy subjects (11 Females and 4 males, Age: 21 ± 2 y) where SCG, ECG, and spirometry were simultaneously acquired. SCG waveform variability was calculated at each experimental state (i.e., lung volume and airway pressure). Results showed that breath holding was more effective in reducing the intra-state variability of SCG than clustering normal breathing data. For the BH states, the intra-state variability increased as the airway pressure deviated from zero. The subaudible-to-audible energy ratio of the BH states increased as the airway pressure decreased below zero which may be related to the effect of the intrathoracic pressure on cardiac afterload and blood ejection. When combining the BH waveforms at end inspiration and end expiration states (at the same airway pressures) into one group, the intra-state variability increased, which suggests that the lung volume and associated change in heart location were a significant source of variability. The linear trend between airway pressure and waveform changes was found to be statistically significant for BH at end expiration. To confirm these findings, more studies are needed with a larger number of airway pressure levels and larger number of subjects.
More Related Videos
08:25Combining Volumetric Capnography And Barometric Plethysmography To Measure The Lung Structure-function Relationship
Published on: January 8, 2019
08:44Author Spotlight: Integrating Alveolar-Capillary Reserve Measurements in Exercise Adaptation and Therapeutic Strategies
Published on: February 2, 2024
Related Concept Videos
Respiratory Volumes
Tidal Volume (TV) Tidal volume (TV) is the air inhaled or exhaled in a...
Alterations in Respiration II
In Biot's breathing, the respiratory rate and depth are irregular, alternating between periods of deep gasping and apnea. Common causes...
Physical Assessment of the Respiratory Tract II: Inspection
Chest Configuration
The chest configuration...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Respiratory Volumes and Capacities
Respiratory Volumes and Capacities I