Related Experiment Video
Updated: Jun 18, 2025

Soil Lysimeter Excavation for Coupled Hydrological, Geochemical, and Microbiological Investigations
Published on: September 11, 2016
Leachate reduction and pollution control strategies for landfills in hilly areas based on site condition analysis and
Zhongle Cheng1, Fugang Wang1, Yaohui Wang1
1Key Laboratory of Groundwater Resources and Environment, Ministry of Education, Jilin University, Changchun, 130012, China; Jilin Provincial Key Laboratory of Water Resources and Water Environment, Jilin University, China.
Abstract:
Landfill is an important means of municipal solid waste treatment. Previous studies have shown that the combination of "cut-off wall and pumping well" technology is an effective measure to deal with the leachate emission reduction and pollution control of landfill, and has been widely used in plain areas. However, for landfills in hilly areas with complex terrain and geological conditions, there is still a lack of clear and referable ideas and operational strategies for leachate emission reduction and pollution control. In this study, we proposed strategies for determining the position and depth of cut-off walls and pumping wells and reasonable combinations of the cut-off wall depth and pumping quantity for leachate reduction and pollution prevention of landfills in hilly areas. The determination of leachate reduction and pollution control strategy need to be achieved in two stages, qualitative and quantitative: (1) In the qualitative stage, the natural conditions (Weathering degree, groundwater flow characteristics, topography condition, hydrometeor condition, and aquifer thickness) and engineering conditions (Operation status, landfill location, and excavation status) of the study area are analysed in detail, and then the depth range and location of the cut-off wall and pumping well are determined. (2) In the quantitative stage, we need to quantify the combination of the cut-off wall depth and pumping quantity by using profile particle tracing and pollutant transport modelling. A reasonable cut-off wall depth needs to control the leakage of pollutants inside the wall, and a reasonable pumping quantity needs to ensure that the depth of the pollutant distribution is equivalent to the depth of the separation line, which separates the water flow towards the pumping well and the water flow downstream. (3) The effectiveness of the leachate reduction and prevention strategies proposed in this study was verified through an example of a landfill in Northeast China. This study provides a reference and operation method for leachate emission reduction and pollution control of landfills in hilly areas.
More Related Videos
Related Concept Videos
Bioremediation
Design Example: Maintaining Level of an Embankment
Design Example: Analyzing Capacity Contours for Flood Risk Assessment

