BOOM: A novel bifurcation stent technique using optical coherence tomography co-registration
Alec Goldberg1, Evan Shlofmitz2, Fernando Sosa2
1St. Francis Hospital & Heart Center, Roslyn, New York, United States of America; Tulane University School of Medicine, New Orleans, LA, United States of America.
Background/Purpose:
Bifurcation lesions comprise 20 % of percutaneous coronary interventions (PCI) and are associated with worse long-term outcomes. With an increasing percentage of patients presenting with complex anatomy, including bifurcation disease, there is a need for treatment strategies to optimize PCI outcomes.
Methods/Materials:
We retrospectively analyzed 48 patients undergoing OCT guided bifurcation PCI using the 'Bifurcation and Ostial OCT Mapping' (BOOM) technique. The primary efficacy variable studied was stent precision following deployment, defined as the distance of the most proximal stent strut from the true ostium of the target vessel. Additionally, targeted follow-up occurred by phone at 6- and 12-months post procedure, where the frequency of myocardial infarction, target lesion revascularization, target vessel and non-target vessel revascularization, and mortality were collected.
Results:
A total of 40 (83.3 %) had an ostial lesion that required treatment while the remaining patients had true bifurcation disease. Most target lesions were in either the LAD or its branches (29 lesions (60.3 %)). With respect to stent positioning, the median absolute geographic miss, (i.e., stent protrusion into the main branch or lack of complete ostial stent coverage), was 0.75 mm. At 6 months, one patient required target lesion revascularization with no additional patients at 12 months.
Conclusions:
BOOM is a safe and simple strategy that can be a useful technique to optimize precise stent placement for ostial and bifurcation lesions.
More Related Videos
13:07Optical Coherence Tomography Based Biomechanical Fluid-Structure Interaction Analysis of Coronary Atherosclerosis Progression
Published on: January 15, 2022
13:48Reduction of Radiation Exposure during Endovascular Treatment of Peripheral Arterial Disease Combining Fiber Optic RealShape Technology and Intravascular Ultrasound
Published on: April 21, 2023
Related Concept Videos
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies III: Computed Tomography
Imaging Studies VII: Vascular Imaging