Real-time gamma-ray energy spectrum / dose monitor with k-α method based on sequential bayesian estimation
Isao Murata1, Nikolaos Voulgaris1, Takaaki Miyoshi1
1Division of Sustainable Energy and Environmental Engineering, Graduate School of Engineering, Osaka University, Yamadaoka 2-1, Suita Osaka, Japan.
Abstract:
Medical applications of radiation have been widely spread until now. However, the exposure of medical staff is sometimes overlooked, because treatment of patients is the first priority. The purpose of this study is to develop a small and light monitor that can measure the energy spectrum and dose of gamma-rays at the same time in real-time for medical applications. Using the monitor, the medical staff could be guided to be more aware ofthe risk of radiation, and finally the exposure to them could be substantially suppressed. So far, a CsI scintillator has been chosen as a detection device of gamma-rays and combined with a Multi-Pixel Photon Counter (MPPC) to develop a prototype monitor. Then we confirmed its basic performance with standard gamma-ray sources. To achieve the real-time measurement, α method (sequential Bayesian estimation) was adopted and improved to propose a new unfolding process, named k-α method, with which the convergence speed could really be accelerated to realize real-time measurement. Also, gamma-ray measurements with a mixed source of 133Ba, 137Cs and 60Co were carried out to confirm the validity of the present monitor. As a result, it was found that gamma-ray energy spectrum could be estimated successfully in several-tens seconds in the field of around 6 μSv/h. For the dose estimation, the correct values could be estimated just after starting measurement.
More Related Videos
10:33Expedited Radiation Biodosimetry by Automated Dicentric Chromosome Identification ADCI and Dose Estimation
Published on: September 4, 2017
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
Related Concept Videos
Atomic Emission Spectroscopy: Overview
Biological Effects of Radiation
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Atomic Emission Spectroscopy: Lab
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....