Related Experiment Video
Updated: Jun 17, 2025

07:29
Three Different Protocols of Corneal Collagen Crosslinking in Keratoconus: Conventional, Accelerated and Iontophoresis
Published on: November 12, 2015
19.9K
Comparison of Predictability in Vault Using NK Formula and KS Formula for the Implantable Collamer Lens Surgery
Xin Zhong1, Yan Li1, Yuancun Li1
1Joint Shantou International Eye Center of Shantou University The Chinese University of Hong Kong, Shantou, China.
Journal of Ophthalmology
|August 6, 2024
Summary
The NK and KS formulas inaccurately predict the vault after implantable collamer lens (ICL) surgery, with achieved vaults being smaller than predicted. Relying solely on these formulas for vault prediction is not recommended.
Area of Science:
- Ophthalmology
- Biomedical Engineering
- Optical Engineering
Background:
- Implantable collamer lenses (ICLs) are used for refractive error correction.
- Accurate prediction of postoperative vault is crucial for ICL safety and efficacy.
- The NK and KS formulas are commonly used to predict vault, but their agreement needs investigation.
Purpose of the Study:
- To investigate the agreement between the NK and KS formulas in predicting the postoperative vault after EVO-ICL implantation.
- To compare the predictive accuracy of the NK and KS formulas.
- To identify factors influencing achieved vault post-ICL surgery.
Main Methods:
- Retrospective study of 106 eyes (57 patients) undergoing EVO-ICL-V4c implantation.
- Preoperative vault prediction using NK and KS formulas.
- Postoperative vault measurement using anterior segment optical coherence tomography (AS-OCT) at one month.
- Analysis of vault prediction accuracy and correlation with biometric parameters.
Main Results:
- Achieved vaults were significantly smaller than predicted by both NK and KS formulas (P < 0.05).
- Mean differences between achieved and predicted vaults were -104.82 µm (NK) and -68.55 µm (KS).
- Anterior chamber depth, V-STS diameter, and CLR were associated with achieved vault; no significant difference in absolute prediction error between formulas.
Conclusions:
- The NK formula showed better consistency than the KS formula for the 12.6 mm ICL size.
- AS-OCT measurements overestimated predicted ICL vault, particularly with 13.2 mm ICLs.