Wearable Blood Pressure Monitoring Devices: Understanding Heterogeneity in Design and Evaluation
Objective:
Rapid advances in cuffless blood pressure (BP) monitoring have the potential to radically transform clinical care for cardiovascular health. However, due to the large heterogeneity in device design and evaluation, it is difficult to critically and quantitatively evaluate research progress. In this two-part manuscript, we provide a principled way of describing and accounting for heterogeneity in device and study design.
Methods:
We first provide an overview of foundational elements and design principles of three critical aspects: 1) sensors and systems, 2) pre-processing and feature extraction, and 3) BP estimation algorithms. Then, we critically analyze the state-of-the-art methods via a systematic review.
Results:
First, we find large heterogeneity in study designs, making fair comparisons extremely challenging. Moreover, many study designs have data leakage and are underpowered. We suggest a first open-contribution BP estimation benchmark for standardization. Next, we observe that BP distribution in the study sample and the time between calibration and test in emerging personalized devices confound BP estimation error. We suggest accounting for these using a convenient metric coined "explained deviation". Finally, we complement this manuscript with a website, https://wearablebp.github.io, containing a bibliography, meta-analysis results, datasets, and benchmarks, providing a timely plaWorm to understand state-of-the-art devices.
Conclusion:
There is large heterogeneity in device and study design, which should be carefully accounted for when designing, comparing, and contrasting studies.
Significance:
Our findings will allow readers to parse out the heterogeneous literature and move toward promising directions for safer and more reliable devices in clinical practice and beyond.
More Related Videos
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Errors occurring during blood pressure monitoring
Several factors...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Pre-Procedural Guidelines for Assessing Blood Pressure
Measurement of Blood Pressure