Current guidelines recommend D-dimer for acute aortic syndrome (AAS). This review found few alternative biomarkers with consistent accuracy, indicating they are not yet ready for clinical use in AAS diagnosis.

Area of Science:

  • Emergency Medicine
  • Cardiovascular Diagnostics
  • Biomarker Research

Background:

  • D-dimer is the sole recommended biomarker for diagnosing acute aortic syndrome (AAS).
  • This systematic review aimed to identify and evaluate alternative biomarkers for AAS diagnosis.
  • Investigating novel diagnostic markers is crucial for improving patient outcomes.

Approach:

  • Systematic review of electronic databases (MEDLINE, EMBASE, Cochrane Library) up to February 2024.
  • Included diagnostic cohort studies examining biomarkers other than D-dimer for AAS.
  • Excluded case-control studies due to high risk of bias; assessed quality using QUADAS-2 tool.

Key Points:

  • 13 cohort studies were included, with variable methodological quality and risk of bias.
  • Only two studies reported biomarkers with sensitivity and specificity comparable to D-dimer.
  • Soluble ST2 and neutrophil count showed potential but lacked consistent validation across studies.

Conclusions:

  • Numerous potential alternative biomarkers for AAS exist.
  • Few have been evaluated in multiple studies, and study designs are often weak.
  • Current alternative biomarkers are not sufficiently accurate or consistent for routine clinical use in AAS diagnosis.