Related Experiment Video
Updated: Jun 17, 2025

Ex Vivo Porcine Experimental Model for Studying and Teaching Lung Mechanics
Published on: April 19, 2024
Adaptive Pressure Control-Continuous Mandatory Ventilation Versus Volume Control-Continuous Mandatory Ventilation:
Linh N Tran1, Jared E Rosen2, Alex K Pearce3
1Division of Pulmonary, Critical Care and Sleep Medicine, University of California, San Diego, School of Medicine, La Jolla, California. Lit004@ucsd.edu.
Background:
Adaptive pressure control-continuous mandatory ventilation (APC-CMV) is a frequently utilized ventilator mode in ICU settings. This analysis compared APC-CMV and traditional volume control-continuous mandatory ventilation (VC-CMV) mode, describing factors associated with initiation, maintenance, and changes in settings of each mode.
Methods:
We analyzed ventilator data from a retrospective electronic health record data set collected as part of a quality improvement project in a single academic ICU. The majority ventilator mode was defined as the mode comprising the highest proportion of mechanical ventilation time. Multivariable logistic regression was used to identify variables associated with initial and majority APC-CMV or VC-CMV modes. Wilcoxon rank-sum tests were used to compare ventilator setting changes/d and sedation as a function of APC-CMV and VC-CMV majority modes.
Results:
Among 1,213 subjects initiated on mechanical ventilation from January 2013-March 2017, 68% and 24% were initiated on APC-CMV and VC-CMV, respectively, which composed 62% and 21% of the majority ventilator modes. Age, sex, race, and ethnicity were not associated with the initial or majority APC-CMV or VC-CMV modes. Subjects initiated on APC-CMV spent 88% of the mechanical ventilation time on APC-CMV mode. Compared to VC-CMV, subjects with APC-CMV majority mode experienced more ventilator setting changes/d (1.1 vs 0.8, P < .001). There were no significant differences in sedative medications when comparing subjects receiving APC-CMV versus VC-CMV majority modes.
Conclusions:
APC-CMV was highly utilized in the medical ICU. Subjects on APC-CMV had more ventilator setting changes/d than those on VC-CMV. APC-CMV offered no advantage of reduced setting adjustments or less sedation compared to VC-CMV.
Related Concept Videos
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Mechanical Ventilation I: Indication and Settings
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Physiological Control of Respiration
Breathing, a seemingly passive process, is regulated by the respiratory center in the brainstem. This center coordinates the involuntary control of respirations, which means it occurs without conscious effort, ensuring a smooth and uninterrupted pattern.
Regulation of Ventilation
The body maintains ventilation by monitoring levels of carbon dioxide (CO2), oxygen (O2), and hydrogen ion concentration (pH) in the arterial blood. Among these factors, the level of CO2 plays a crucial...
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...