Related Experiment Video
Updated: Jun 17, 2025

Aerosol-assisted Chemical Vapor Deposition of Metal Oxide Structures: Zinc Oxide Rods
Published on: September 14, 2017
The O-Defective g-ZnO Sensor for VOC Gases: The Adsorption-Desorption, Electronic, and Sensitivity Properties
Yang Shen1, Pei Yuan1, Zhihao Yuan1
1School of Science, Xi'an University of Technology, Xi'an 710054, China.
Abstract:
Adsorption-desorption performance, electronic properties, and sensitivity of O-defective g-ZnO (ODZO) gas sensors for volatile organic compounds (VOCs) are calculated using density functional theory and nonequilibrium Green's formalism. The VOCs are CH2O, CH4, C2H4O, CH4O, and C2H6. The intrinsic g-ZnO (IZO) and ODZO exhibit strong adsorption capabilities for C2H4O and CH4O. The IZO (0.118 e) and ODZO (0.059 e), which act as electron donors, exhibit the highest charge transfer to CH2O, indicating a strong interaction. The VOCs adsorption on the IZO and ODZO systems maintain nonmagnetic semiconductor characteristics. Additionally, the introduction of an O-defect causes the adsorption energy and charge transfer amount of ODZO to show an overall decrease, indicating better desorption ability. Notably, the sensitivity results show that the ODZO gas sensors exhibit high sensitivity to CH2O (39.3%), C2H4O (29.0%), and CH4O (19.6%) at a voltage of 2.6 V, consistent with the adsorption-desorption performance and electronic properties.
More Related Videos
08:18Synthesis and Characterization of High c-axis ZnO Thin Film by Plasma Enhanced Chemical Vapor Deposition System and its UV Photodetector Application
Published on: October 3, 2015
11:38In situ FTIR Spectroscopy as a Tool for Investigation of Gas/Solid Interaction: Water-Enhanced CO2 Adsorption in UiO-66 Metal-Organic Framework
Published on: February 1, 2020
Related Concept Videos
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Types of Detectors-II
High-Performance Liquid Chromatography: Types of Detectors
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Atomic Absorption Spectroscopy: Instrumentation
The atomizer used in AAS can be either a flame atomizer or an...