Related Experiment Video
Updated: Jun 17, 2025

A Sectioning, Coring, and Image Processing Guide for High-Throughput Cortical Bone Sample Procurement and Analysis for Synchrotron Micro-CT
Published on: June 12, 2020
Assessment of differences in mechanical properties and thickness of temporal and occipital bones and correlation with
Suguru Torimitsu1, Yoshifumi Nishida2, Daisuke Yajima3
1Department of Forensic Medicine, Graduate School of Medicine, The University of Tokyo, 7-3-1, Hongo, Bunkyo-ku, Tokyo 113-0033, Japan; Education and Research Center of Legal Medicine, Graduate School of Medicine, Chiba University, 1-8-1, Inohana, Chuo-ku, Chiba 260-8670, Japan.
Abstract:
The mechanical properties and thickness of adult temporal and occipital bones were examined in modern Japanese forensic samples. Cranial bones were obtained from 293 Japanese corpses (179 men and 114 women). During autopsy, left temporal (LT), right temporal (RT), and occipital (O) bone samples were extracted from each skull. Sample thickness (ST) was measured using multidetector computed tomographic imaging. The fracture load (FL) of each sample was measured by a bending test, in which the flexural strength (FS) was calculated. The FL and ST values for O were significantly greater compared with those of the LT and RT bones. The temporal bones were thinner compared with other parts of the skull and at greater risk for fracture. There is a need to take precautions to prevent temporal bone fractures. There were no significant differences in any of the values between LT and RT, indicating bilateral symmetry of the temporal bones. There were significant negative correlations between age and the FL and FS values for all sites in both sexes, except for O in the male samples, suggesting that older individuals are at increased risk for fractures. No significant correlations were observed between age and ST values in any of the samples. There were significantly positive correlations between FL and ST values at all sites regardless of sex.
Related Concept Videos
Sutures of the Skull
Sutures are immobile joints between adjacent bones of the skull. The narrow gap between the bones is filled with dense, fibrous connective tissue that unites the bones. The long sutures located between the skull bones are not straight but instead follow irregular, tightly twisting paths. These twisting lines tightly...
Bone Disorders
Bone deposition is also affected by the levels of sex hormones like estrogen and testosterone that promote osteoblast activity and bone matrix synthesis. When the level of these hormones decreases due to aging, it causes a reduction in bone deposition. As a result, bone resorption by osteoclasts...

