Generating and monitoring mild hyperthermia using a ring array ultrasound transducer
David Bustamante1, Yan Yan2, Trevor Mitcham2
1Department of Biomedical Engineering, Hajim School of Engineering and Applied Sciences, University of Rochester, Rochester, New York, USA.
Objective:
To demonstrate the feasibility of using a ring array ultrasound (US) transducer, guided by ultrasound tomography (UST), for generating and monitoring mild hyperthermia (MHTh).
Methods:
In silico and in vitro experiments were designed to evaluate the efficacy of a ring array US transducer for generating MHTh and monitoring changes in temperature. In a series of in silico studies, we compared the acoustic focal profiles produced by a ring array US transducer transmitting at different frequencies and further investigated the effectiveness of UST-guidance in implementing aberration correction to enhance the focal profile. In vitro experiments evaluated the capability of using a ring array US transducer to generate and maintain MHTh and the accuracy of using UST to monitor temperature changes.
Results:
The simulations demonstrated that a ring array US transducer achieves symmetrical and localized acoustic focusing. In a heterogenous tissue model, a ring array US transducer achieved a superior acoustic focus by implementing aberration correction with guidance from UST. In vitro experiments demonstrated the capability of a ring array US transducer to generate MHTh in a tissue-mimicking phantom in an average of 117 ± 18 s and subsequently maintain MHTh. Lastly, a ring array US transducer utilized UST to track temperature changes in a preheated water-filled inclusion while it passively cooled from 45 °C to 25 °C, with a maximum error of 0.58 °C.
Conclusion:
A ring array US transducer can noninvasively generate and monitor MHTh, overcoming many limitations of current clinical systems. The closed geometry of the transducer is optimal for acoustic focusing and UST-guidance allows for improved aberration correction in a heterogenous medium. Utilizing UST thermometry with the same ring array US transducer will allow for implementing an image-guided, temperature-controlled, all-acoustic MHTh system.
More Related Videos
09:01Magnetic-, Acoustic-, and Optical-Triple-Responsive Microbubbles for Magnetic Hyperthermia and Pothotothermal Combination Cancer Therapy
Published on: May 22, 2020
06:43Esophageal Heat Transfer for Patient Temperature Control and Targeted Temperature Management
Published on: November 21, 2017
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Increased Body Temperature
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...