Hardware-in-the-Loop experiments in model ice for analysis of ice-induced vibrations of offshore structures
1Department of Hydraulic Engineering, Faculty of Civil Engineering and Geosciences, Delft University of Technology, Stevinweg 1, 2628 CN, Delft, The Netherlands. t.c.hammer@tudelft.nl.
Abstract:
The study investigated the use of a Hardware-in-the-Loop (HiL) technique applied in model ice experiments to enable the analysis of offshore structures with low natural frequencies under dynamic ice loading. Traditional approaches were limited by facility capacities and ineffective downscaling of the geometry of the offshore structures. The goal of the present study was to overcome these challenges and to enhance the understanding and explore the applicability of a hybrid testing technique in model ice experiments. To achieve the objective, 204 Hardware-in-the-Loop simulations in model Ice (HiLI) were analyzed. Results showed robust behavior and good performance of the HiLI due to minimal variation in measured delay, normalized root mean square error, and peak tracking error and low magnitudes of such parameters despite alterations in factors such as the choice of the numerical structural model, physical prototype, measurement system, and ice type. Notably, the performance of the HiLI was affected when testing with warm model ice or scaling for harsh ice conditions, attributed to a reduced signal-to-noise ratio and instability of the system, respectively. Experimental identification of the critical delay, along with the application of an analytical stability criterion, revealed that the instability observed, was likely induced by reducing the structural stiffness of the numerical structural model to fulfil the scaling requirements when testing for harsh ice conditions. Additionally, the study showed improved HiLI performance when the physical prototype was in contact with the model ice. This observation was further analyzed and is assumed to be caused by the coupling between the ice and physical prototype, causing a coupled and thus increased eigenfrequency of the physical prototype-ice system.
More Related Videos
Related Concept Videos
Dynamic Modulus of Elasticity of Concrete
The sonic test is a common method to determine the dynamic modulus. In this test, a concrete beam, sized either 6 x 6 x 30 inches or 4 x 4 x 20 inches, is clamped at its center. Vibrations are initiated at one end of the beam by an electromagnetic exciter unit powered by a...
Typical Model Studies