Related Experiment Video
Updated: Jun 20, 2026

C-arm-Free Simultaneous OLIF51 and Percutaneous Pedicle Screw Fixation in a Single Lateral Position
Published on: September 16, 2022
Transobturator-cable-fixation in pelvic ring injuries with symphyseal disruption - a last resort?
Martin C Jordan1,2, Richard Wagner3, Lukas Hufnagel3
1Department of Orthopaedic Trauma, Hand, Plastic and Reconstructive Surgery, University Hospital Würzburg, Oberdürrbacherstraße 6, 97080, Würzburg, Germany. Jordan_m@ukw.de.
Purpose:
The role of transobturator-cable-fixation (TOCF) in traumatic symphyseal rupture of the pelvic ring remains unclear. This case series aims to evaluate TOCF in complex and revision cases in pelvic surgery.
Methods:
A retrospective analysis of a chronological case series was conducted, studying pelvic fractures stabilized using TOCF between January 2006 and December 2022. The variables considered included age, gender, fracture classification, Injury Severity Score (ISS), Body Mass Index (BMI), trauma mechanism, time to surgery, fixation technique, hospital duration, complications, status on discharge (Glasgow Outcome Scale; GOS), follow-up time and indication for the use of TOCF.
Results:
All patients (N = 7) were male with a mean age of 64 years and a mean BMI of 29. The mean ISS was 45, with the lowest ISS of 25, indicating that only polytraumatized patients were included. Two anterior-posterior-compression-, four lateral-compression-, and one vertical-shear-pelvic-injury were identified. TOCF was added in six cases to support symphyseal plating and in one case to external fixation. The mean hospital stay was 49 days and the mean follow-up duration was 8.5 months. No complications associated with TOCF were observed during the surgical procedure or follow-up.
Conclusion:
TOCF showed no procedure-associated complications and effectively supported symphyseal healing in all cases. The main indications were obesity, poor bone quality in elderly patients, and revision cases. TOCF could be considered as a last treatment option in open-book pelvic injuries where plating or external fixation is at risk to fail.
More Related Videos
04:19Minimally Invasive Treatment for Thoracolumbar Burst Fracture Using Sagittal Alignment Screws and A Trauma Reduction Device
Published on: November 8, 2024
03:30Author Spotlight: Advancing Pelvic Prolapse Treatment with a Non-Mesh Approach using Laparoscopic Pectopexy
Published on: October 25, 2024
Related Concept Videos
Restarting Stalled Replication Forks
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the procedure...
Reclosers and Fuses
A comprehensive protection scheme for radial distribution...