Related Experiment Video
Updated: Jun 20, 2026

Dynamic Lung Tumor Tracking for Stereotactic Ablative Body Radiation Therapy
Published on: June 7, 2015
In Silico Comparison of Three Different Beam Arrangements for Intensity-Modulated Proton Therapy for Postoperative
Emile Gogineni1,2, Hao Chen2, Ian K Cruickshank2
1Department of Radiation Oncology, The Ohio State University Wexner Medical Center, Columbus, OH 43210, USA.
Abstract:
Background and purpose: Proton therapy has been shown to provide dosimetric benefits in comparison with IMRT when treating prostate cancer with whole pelvis radiation; however, the optimal proton beam arrangement has yet to be established. The aim of this study was to evaluate three different intensity-modulated proton therapy (IMPT) beam arrangements when treating the prostate bed and pelvis in the postoperative setting. Materials and Methods: Twenty-three post-prostatectomy patients were planned using three different beam arrangements: two-field (IMPT2B) (opposed laterals), three-field (IMPT3B) (opposed laterals inferiorly matched to a posterior-anterior beam superiorly), and four-field (IMPT4B) (opposed laterals inferiorly matched to two posterior oblique beams superiorly) arrangements. The prescription was 50 Gy radiobiological equivalent (GyE) to the pelvis and 70 GyE to the prostate bed. Comparisons were made using paired two-sided Wilcoxon signed-rank tests. Results: CTV coverages were met for all IMPT plans, with 99% of CTVs receiving ≥ 100% of prescription doses. All organ at risk (OAR) objectives were met with IMPT3B and IMPT4B plans, while several rectum objectives were exceeded by IMPT2B plans. IMPT4B provided the lowest doses to OARs for the majority of analyzed outcomes, with significantly lower doses than IMPT2B +/- IMPT3B for bladder V30-V50 and mean dose; bowel V15-V45 and mean dose; sigmoid maximum dose; rectum V40-V72.1, maximum dose, and mean dose; femoral head V37-40 and maximum dose; bone V40 and mean dose; penile bulb mean dose; and skin maximum dose. Conclusion: This study is the first to compare proton beam arrangements when treating the prostate bed and pelvis. four-field plans provided better sparing of the bladder, bowel, and rectum than 2- and three-field plans. The data presented herein may help inform the future delivery of whole pelvis IMPT for prostate cancer.
More Related Videos
08:34Proton Therapy Delivery and Its Clinical Application in Select Solid Tumor Malignancies
Published on: February 6, 2019
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies III: Computed Tomography