Fabrication of Apparatus Specialized for Measuring the Elasticity of Perioral Tissues
Ryo Takemoto1, Junya Kobayashi2, Yuko Oomori3
1Division of Orthodontics, Faculty of Dentistry & Graduate School of Medical and Dental Sciences, Niigata University, Niigata 951-8514, Japan.
Abstract:
On the human face, the lips are one of the most important anatomical elements, both morphologically and functionally. Morphologically, they have a significant impact on aesthetics, and abnormal lip morphology causes sociopsychological problems. Functionally, they play a crucial role in breathing, articulation, feeding, and swallowing. An apparatus that can accurately and easily measure the elastic modulus of perioral tissues in clinical tests was developed, and its measurement sensitivity was evaluated. The apparatus is basically a uniaxial compression apparatus consisting of a force sensor and a displacement sensor. The displacement sensor works by enhancing the restoring force due to the deformation of soft materials. Using the apparatus, the force and the displacement were measured for polyurethane elastomers with various levels of softness, which are a model material of human tissues. The stress measured by the developed apparatus increased in proportion to Young's modulus, and was measured by the compression apparatus at the whole region of Young's modulus, indicating that the relation can be used for calibration. Clinical tests using the developed apparatus revealed that Young's moduli for upper lip, left cheek, and right cheek were evaluated to be 45, 4.0, and 9.9 kPa, respectively. In this paper, the advantages of this apparatus and the interpretation of the data obtained are discussed from the perspective of orthodontics.
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Measurements of Strain