Ultrasonographic Evaluation of Breast Cancer-related Lymphedema
Published on: January 12, 2017
Pitting Is Not Only a Measure of Oedema Presence: Using High-Frequency Ultrasound to Guide Pitting Test
Jennifer Sanderson1,2, Neil Tuttle2, Robyn Box3
1Menzies Health Institute Queensland, Griffith University, Gold Coast, QLD 4215, Australia.
Abstract:
The pitting qualities of lymphoedema tissue change with disease progression. However, little is known about the underlying tissue response to the pitting test or the tissue characteristics that enhance or resist indentation. The pitting test is currently unstandardised, and the influence of test technique on pitting outcomes is unknown. Understanding how tissue reacts to applied pressure will build evidence for the standardisation of the pitting test. Ninety pitting test sites from fifteen women with unilateral breast cancer-related lymphoedema were evaluated using high-frequency ultrasound (HFUS), bioelectrical impedance spectroscopy (BIS), and limb volume measures. Three sites on each lymphoedema and non-lymphoedema arm were subject to a 60-s (s) staged pitting test, with changes in tissue features captured with ultrasound imaging before, throughout, and after the pitting test. Pitting qualities of tissues varied greatly, with lymphoedema sites pitting more frequently (p < 0.001) with greater depth (p < 0.001) and requiring a longer recovery time (p = 0.002) than contralateral unaffected tissue. Pitting is not solely attributable to oedema volume. Non-structural and structural characteristics of dermal and subcutaneous layers also influence tissue responses to sustained pressure. To enhance the validity and reliability of pitting assessment, a 60 s staged pitting test with an observation of tissue recovery is recommended for lymphoedema presentations.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...