Related Experiment Video
Updated: Jun 17, 2025

A Methodological Approach to Non-invasive Assessments of Vascular Function and Morphology
Published on: February 7, 2015
Assessments of arterial and venous phase radiodensity does not improve carotid near-occlusion diagnostics
Karolina Brunnander1, Alexander Henze2, Allan J Fox3
1Clinical Science, Umeå University, Umeå, Sweden.
Abstract:
The hypothesis of this study was that evaluation of radiodensity assessment beyond a carotid stenosis in arterial and/or venous phase can be used to separate near-occlusion and conventional ≥ 50% stenosis. We prospectively included participants with ≥ 50% carotid stenosis with inclusion preference for cases with extracranial internal carotid artery (ICA) asymmetry. All participants were examined with a research biphasic computed tomography angiography (CTA) protocol (arterial and venous phase). Reference diagnosis was set by interpretation on CTA and radiodensity difference between ipsilateral and contralateral ICA (c-corrected) or vertebral (v-corrected) was compared. We included 93 participants, 62 with near-occlusion and 31 with conventional ≥ 50% stenosis. Just beyond the stenosis, median c-corrected radiodensity was - 20 Hounsfield units (HU) among near-occlusions and - 1 HU among conventional ≥ 50% stenoses (p < 0.001) in the arterial phase. For the venous phase, these findings were + 17 HU and + 3 HU (p = 0.007). Similar group differences were seen for v-correction. No parameter had good diagnostic performance, area under the curve ≤ 0.82. With specificity set at ≥ 95%, detected near-occlusions were foremost those with large side-to-side differences in distal ICA-diameter. Carotid near-occlusions can have reduced radiodensity beyond the stenosis in arterial phases and increased radiodensity in venous phases compared to a reference artery-which was not clearly seen for conventional stenoses. However, these radiodensity findings are best seen in near-occlusion cases that are not diagnostically challenging, while they work poorly as additional diagnostic aids.
Related Concept Videos
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Assessment of blood pressure in brachial artery(two-step method)
Assessment of the Cardiovascular System II: Inspection
Head and Neck
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...

