Related Experiment Video
Updated: Jun 17, 2025

Author Spotlight: Expanding Interventional Pulmonology Research with Robotic-Assisted Bronchoscopy
Published on: July 19, 2024
Assessing risk factors for complications in computer tomography-guided lung biopsy: quantitative analysis for
Jie Zhang1, Jianli An2, Xiuxiu Jing2
1From the Department of Infectious Diseases, First Hospital of Qinhuangdao, Qinhuangdao, Hebei, China.
Background:
Computer tomography (CT)-guided lung biopsy carries the risk of pneumothorax. A variety of other risk factors affect the occurrence of pneumothorax.
Objective:
Assess the incidence and risk factors associated with pneumothorax complications in CT-guided lung biopsy, and to conduct a quantitative analysis of the variables among the significant risk factors to identify more effective indicators for predicting pneumothorax complications.
Design:
Retrospective logistic.
Setting:
Single center in China.
Patients And Methods:
From June 2017 to May 2021, consecutive patients who underwent CT-guided lung biopsy were identified from the medical record system. Binary logistic regression analysis was used to identify potential risk factors for pneumothorax. Receiver operating characteristic (ROC) curves were constructed for continuous variables to determine cutoff values that optimized sensitivity and specificity.
Main Outcome Measures:
The incidence and risk factors of pneumothorax in CT-guided lung biopsy.
Sample Size:
132 patients.
Results:
The incidence of pneumothorax was 28.9% (38/132), with 6.8% (9/132) of patients requiring chest tube insertion. Results indicated that smaller lesion size (OR 0.724; 95% CI 0.619-0.848; P=.0001), longer needle tract length (OR 1.320; 95% CI 1.145-1.521; P=.001), multiple passes through the pleura (OR 4.618; 95% CI 1.378-15.467; P=.013), and needle tract length/lesion diameter (L/D) ratio (OR 0.028; 95% CI 0.002-0.732; P=.007) were independent risk factors for pneumothorax. ROC curve analysis determined a cut-off value of 0.81 for the L/D ratio (sensitivity=89.5%, specificity=71.3%). The area under the ROC curve (AUC) values of maximum diameter, needle tract length, and L/D ratio for pneumothorax were 0.749, 0.812, and 0.850, respectively.
Conclusions:
The L/D ratio, multiple passes through the pleura, longer needle tract length, and smaller lesions were independent risk factors for pneumothorax. A L/D ratio of less than 0.81 may indicate a pneumothorax. It may be necessary to use the proper sealing procedure for this patient group.
Limitations:
Due to its retrospective nature, there may be inherent selection bias.
More Related Videos
08:05Lung CT Segmentation to Identify Consolidations and Ground Glass Areas for Quantitative Assesment of SARS-CoV Pneumonia
Published on: December 19, 2020
05:50International Expert Consensus and Recommendations for Neonatal Pneumothorax Ultrasound Diagnosis and Ultrasound-guided Thoracentesis Procedure
Published on: March 12, 2020
Related Concept Videos
Pneumothorax-I
Pneumothorax can be even further classified as spontaneous, traumatic, and tension pneumothorax.
Pneumothorax-II
Clinical Manifestations:
Endoscopic Studies II: Thoracocentesis
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...
Pneumonia III: Complications and Assessment
Endoscopic Studies I: Bronchoscopy and Thoracoscopy
Bronchoscopy
Description
Bronchoscopy is a procedure that involves direct visualization of the larynx, trachea, and bronchi for diagnostic and therapeutic purposes. A flexible fiber optic or rigid bronchoscope is used to carry out the procedure. The fiber-optic bronchoscope is more frequently used due...
Radiological Investigation I: X-ray and CT