Imaging Studies for Cardiovascular System II:Types of Echocardiography01:20

Imaging Studies for Cardiovascular System II:Types of Echocardiography

238
Echocardiography plays a role in assessing cardiac health and detecting heart conditions, with various types providing critical insights for diagnosis and treatment.
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...
238
Radiological Investigation III: Pulmonary Angiogram and PET Scan01:13

Radiological Investigation III: Pulmonary Angiogram and PET Scan

89
Radiological investigations are paramount in the diagnosis and management of various pulmonary diseases. Two essential investigations are the Pulmonary Angiogram and the Positron Emission Tomography (PET) Scan.
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
89

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Prostate Imaging-PET: <sup>18</sup>F-Piflufolastat (Pylarify).

Journal of nuclear medicine technology·2026
Same author

Prostate Imaging-PET: <sup>68</sup>Ga-Gozetotide (Locametz, Illuccix, and Gozellix).

Journal of nuclear medicine technology·2026
Same author

Prostate Imaging-PET: <sup>18</sup>F-Fluciclovine (Axumin).

Journal of nuclear medicine technology·2026
Same author

Prostate Imaging-PET: <sup>18</sup>F-Flotufolastat (Posluma).

Journal of nuclear medicine technology·2026
Same author

Prostate Cancer: <sup>177</sup>Lu-PSMA (Pluvicto).

Journal of nuclear medicine technology·2026
Same author

Breast Imaging: Molecular (MBI).

Journal of nuclear medicine technology·2025

Related Experiment Video

Updated: Jun 17, 2025

In Vivo Quantitative Assessment of Myocardial Structure, Function, Perfusion and Viability Using Cardiac Micro-computed Tomography
08:13

In Vivo Quantitative Assessment of Myocardial Structure, Function, Perfusion and Viability Using Cardiac Micro-computed Tomography

Published on: February 16, 2016

19.5K

Combined Supine-Prone Myocardial Perfusion Imaging: Enhancing Diagnostic Accuracy.

Mary Beth Farrell1

  • 1Intersocietal Accreditation Commission, Ellicott City, Maryland marybethfarrell2016@gmail.com.

Journal of Nuclear Medicine Technology
|August 13, 2024
PubMed
Summary

Adding prone imaging to SPECT myocardial perfusion imaging significantly improves accuracy by differentiating true defects from artifacts. This enhanced protocol optimizes patient care and benefits nuclear cardiology labs.

Keywords:
artifactbreast attenuationdiaphragmatic attenuationmyocardial perfusion imagingpronesupine

More Related Videos

MRI and PET in Mouse Models of Myocardial Infarction
10:46

MRI and PET in Mouse Models of Myocardial Infarction

Published on: December 19, 2013

11.7K
Cardiac Magnetic Resonance for the Evaluation of Suspected Cardiac Thrombus: Conventional and Emerging Techniques
06:29

Cardiac Magnetic Resonance for the Evaluation of Suspected Cardiac Thrombus: Conventional and Emerging Techniques

Published on: June 11, 2019

10.3K

Related Experiment Videos

Last Updated: Jun 17, 2025

In Vivo Quantitative Assessment of Myocardial Structure, Function, Perfusion and Viability Using Cardiac Micro-computed Tomography
08:13

In Vivo Quantitative Assessment of Myocardial Structure, Function, Perfusion and Viability Using Cardiac Micro-computed Tomography

Published on: February 16, 2016

19.5K
MRI and PET in Mouse Models of Myocardial Infarction
10:46

MRI and PET in Mouse Models of Myocardial Infarction

Published on: December 19, 2013

11.7K
Cardiac Magnetic Resonance for the Evaluation of Suspected Cardiac Thrombus: Conventional and Emerging Techniques
06:29

Cardiac Magnetic Resonance for the Evaluation of Suspected Cardiac Thrombus: Conventional and Emerging Techniques

Published on: June 11, 2019

10.3K

Area of Science:

  • Nuclear Cardiology
  • Medical Imaging

Background:

  • SPECT myocardial perfusion imaging (MPI) is crucial for diagnosing coronary artery disease.
  • Supine-only imaging can be limited by attenuation artifacts, particularly in the inferior and anterior walls.
  • These artifacts may be misinterpreted as true perfusion defects, reducing diagnostic accuracy.

Purpose of the Study:

  • To evaluate the benefits of a combined supine-prone imaging protocol for SPECT MPI.
  • To assess the ability of prone imaging to differentiate true perfusion defects from attenuation artifacts.
  • To determine the impact of this protocol on diagnostic specificity and accuracy.

Main Methods:

  • Patients underwent standard supine SPECT MPI.
  • Prone imaging was added when perfusion defects were identified on supine images.
  • Comparison of supine and prone images was performed to identify artifacts versus true defects.

Main Results:

  • The supine-prone protocol effectively distinguished attenuation artifacts from true myocardial perfusion defects.
  • This differentiation led to improved specificity and diagnostic accuracy.
  • The additional time for prone imaging was significantly less than standard supine imaging (20%-40% reduction).

Conclusions:

  • Combined supine-prone SPECT MPI is a valuable protocol for enhancing diagnostic accuracy.
  • It offers substantial benefits, especially for labs without attenuation correction technology.
  • Implementation optimizes patient care by providing more reliable perfusion assessments.