Related Experiment Video
Updated: Jun 17, 2025

Construction of a Wireless-Enabled Endoscopically Implantable Sensor for pH Monitoring with Zero-Bias Schottky Diode-based Receiver
Published on: August 27, 2021
Treating acid reflux without compressing the food passageway: 4-year safety and clinical outcomes with the RefluxStop
László Harsányi1, Zsolt Kincses2, Joerg Zehetner3
1Department of Surgery, Transplantation and Gastroenterology, Semmelweis University, Üllői Út 78, 1082, Budapest, Hungary. harsanyi.laszlo@semmelweis.hu.
Introduction:
RefluxStop is an implantable device for laparoscopic surgical treatment of gastroesophageal reflux disease (GERD) to restore and maintain lower esophageal sphincter and angle of His anatomy without encircling and putting pressure on the food passageway, thereby avoiding side effects such as dysphagia and bloating seen with traditional fundoplication. This study reports the clinical outcomes with RefluxStop at 4 years following implantation of the device.
Methods:
A prospective, single arm, multicenter clinical investigation analyzing safety and effectiveness of the RefluxStop device in 50 patients with chronic GERD.
Results:
Available data are presented for 44 patients at 4 years with the addition of three patients at 3 years carried forward. At 4 years, median GERD-HRQL score was 90% reduced compared to baseline. Two patients (2/44) used regular daily proton pump inhibitors (PPIs) despite subsequent 24-h pH monitoring off PPI therapy yielding normal results. There were no device-related adverse events (AEs), esophageal dilations, migrations, or explants during the entire study period. AEs reported between 1 and 4 years were as follows: one subject with heartburn and a pathologic pH result with device positioned too low at surgery; one subject with dysphagia, thus, 46/47 patients reported no dysphagia-related AEs between years 1 and 4. Two patients (2/47) were dissatisfied with treatment despite normal 24-h pH monitoring, of whom one had manometry-verified dysmotility at 6 months, indicating dissatisfaction for reasons other than acid reflux.
Conclusion:
These results confirm the excellent and already published 1-year results as stable in the long-term, supporting the safety and effectiveness of the RefluxStop device in treating GERD for over 4 years. GERD-HRQL score, pH testing, and PPI usage indicate treatment success without dysphagia or gas-bloating and only minimal incidence of other AEs. This favorably low rate of AEs is likely attributable to RefluxStop's dynamic physiologic interaction and non-encircling nature.
Related Concept Videos
Gastroesophageal Reflux Disease II: Clinical Features and Management
Clinical Manifestations
GERD presents itself in a multitude of ways, with symptoms varying from person to person. The hallmark symptoms are...
Barrett Esophagus-II: Clinical Manifestations and Management
To diagnose Barrett's esophagus, healthcare providers often recommend an endoscopy for those showing symptoms of acid reflux. The procedure...
Esophageal Strictures-II: Clinical Features and Management
Healthcare providers should gather a comprehensive medical history and conduct a physical examination for diagnosis. If esophageal stricture is...
Acid Suppressive Drugs for Peptic Ulcer Disease: Proton Pump Inhibitors
Gastric acid, a potent cocktail of hydrogen and chloride ions, is produced in specialized parietal cells within the...
Peptic Ulcer Disease IV: Management
The therapeutic approach involves ensuring adequate rest, implementing drug therapy, promoting smoking cessation, making dietary modifications, and emphasizing long-term follow-up care.
Pharmacological management
The prevailing therapy for peptic ulcers involves a combination of managing the patient's current...
Gastroesophageal Reflux Disease I: Meaning and Pathophysiology

