Agreement between non-invasive and invasive arterial blood pressure during surgery in the prone position: an error
Takashi Juri1, Koichi Suehiro2, Masayo Takai1
1Department of Anesthesiology, Osaka Metropolitan University Graduate School of Medicine, 1-5-7 Asahimachi, Abenoku, Osaka, Osaka, 545-8586, Japan.
Purpose:
Prone position has recently gained renewed importance as a treatment for acute respiratory distress syndrome and spine and brain surgeries. Our study aimed to perform an error grid analysis to examine the clinical discrepancies between arterial blood pressure (ABP) and non-invasive blood pressure (NIBP) in the prone position and to investigate the risk factors influencing these differences.
Methods:
Error grid analysis was performed retrospectively on 1389 pairs of 100 consecutive prone positioning cases. This analysis classifies the difference between the two methods into five clinically relevant zones, from "no risk" to "dangerous risk". Additionally, multivariable ordinal logistic regression analysis was conducted to evaluate the relationship between the risk zones of mean blood pressure (MBP), as classified by error grid analysis and the covariate of interest.
Results:
Error grid analysis showed that the proportions of measurement pairs in risk zones A-E for systolic blood pressure were 96.8%, 3.2%, 0.1%, 0%, and 0%, respectively. In contrast, the MBP proportions were 74.0%, 25.1%, 0.9%, 0.1%, and 0%. Multivariable ordinal logistic regression analysis revealed that the position of arms (next to the head) was a significant factor (adjusted odds ratio: 4.35, 95% CI: 2.38-8.33, P < 0.001).
Conclusion:
Error grid analysis revealed a clinically unacceptable discrepancy between ABP and NIBP for MBP during prone positioning surgery. The position of the arms next to the head was associated with increased clinical discrepancy between the two MBP measurement methods.
More Related Videos
Related Concept Videos
Pre-Procedural Guidelines for Assessing Blood Pressure
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessment of blood pressure in brachial artery(two-step method)
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment: