Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Gas Chromatography: Types of Detectors-II01:19

Gas Chromatography: Types of Detectors-II

349
In gas chromatography, different detectors are employed to meet specific analytical needs. These detectors are often categorized based on their detection mechanisms and the types of compounds they are best suited to analyze. Thermal Conductivity Detectors (TCD), Flame Ionization Detectors (FID), and Electron Capture Detectors (ECD) represent common categories, each with unique operating principles and applications. However, beyond these, several other detectors are designed for more specialized...
349
Flame Photometry: Lab01:16

Flame Photometry: Lab

222
In a flame photometer, when a solution like potassium chloride is aspirated into the flame, the solvent evaporates, leaving behind dehydrated salt. This salt dissociates into free gaseous atoms in their ground state. Some of these atoms absorb energy from the flame, leading to their excitation. The excited atoms return to the ground state, emitting photons at characteristic wavelengths. Because only electronic transitions are involved, the resulting emission lines are very narrow. The intensity...
222

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Distant Landmarks Used for Navigation by Homing Pigeons.

Life (Basel, Switzerland)·2026
Same author

Mapping the soil microbiome functions shaping wetland methane emissions.

mSystems·2026
Same author

Continuous monitoring of plant water potential: sensor-based approaches and best practices.

The New phytologist·2026
Same author

Electric current-driven heterogeneous microstructures in dual-phase titanium alloys.

Nature communications·2026
Same author

Integrated health surveillance and early warning systems in China under the One Health perspective: progress and challenges.

Science in One Health·2026
Same author

Sea level rise and flooding of hazardous sites in marginalized communities across the United States.

Nature communications·2025

Related Experiment Video

Updated: Jun 17, 2025

Measuring Dissolved Methane in Aquatic Ecosystems Using An Optical Spectroscopy Gas Analyzer
05:00

Measuring Dissolved Methane in Aquatic Ecosystems Using An Optical Spectroscopy Gas Analyzer

Published on: July 26, 2024

413

Measuring Dissolved Methane in Aquatic Ecosystems Using An Optical Spectroscopy Gas Analyzer.

Jorge A Villa1, Robert Bordelon2, Yang Ju3

  • 1School of Geosciences, University of Louisiana at Lafayette; jorge.villa@louisiana.edu.

Journal of Visualized Experiments : Jove
|August 14, 2024
PubMed
Summary
This summary is machine-generated.

This study presents a cost-effective method for measuring dissolved greenhouse gases (GHG) in aquatic systems using portable gas analyzers. The new protocol offers a practical alternative to traditional methods, especially for field research.

More Related Videos

Design and Use of a Full Flow Sampling System FFS for the Quantification of Methane Emissions
08:18

Design and Use of a Full Flow Sampling System FFS for the Quantification of Methane Emissions

Published on: June 12, 2016

16.7K
The Use of an Automated System GreenFeed to Monitor Enteric Methane and Carbon Dioxide Emissions from Ruminant Animals
11:02

The Use of an Automated System GreenFeed to Monitor Enteric Methane and Carbon Dioxide Emissions from Ruminant Animals

Published on: September 7, 2015

21.9K

Related Experiment Videos

Last Updated: Jun 17, 2025

Measuring Dissolved Methane in Aquatic Ecosystems Using An Optical Spectroscopy Gas Analyzer
05:00

Measuring Dissolved Methane in Aquatic Ecosystems Using An Optical Spectroscopy Gas Analyzer

Published on: July 26, 2024

413
Design and Use of a Full Flow Sampling System FFS for the Quantification of Methane Emissions
08:18

Design and Use of a Full Flow Sampling System FFS for the Quantification of Methane Emissions

Published on: June 12, 2016

16.7K
The Use of an Automated System GreenFeed to Monitor Enteric Methane and Carbon Dioxide Emissions from Ruminant Animals
11:02

The Use of an Automated System GreenFeed to Monitor Enteric Methane and Carbon Dioxide Emissions from Ruminant Animals

Published on: September 7, 2015

21.9K

Area of Science:

  • Environmental Science
  • Analytical Chemistry
  • Ecology

Background:

  • Greenhouse gas (GHG) measurements are crucial for climate change research.
  • Existing analytical platforms for GHG fluxes may lack adaptability for aqueous samples.
  • There is a growing need for accessible methods to measure dissolved GHGs in various ecosystems.

Purpose of the Study:

  • To adapt portable optical spectroscopy gas analyzers for measuring GHG concentrations in aqueous samples.
  • To develop a cost-effective and efficient protocol for dissolved GHG analysis.
  • To provide a field-deployable solution for aquatic GHG monitoring.

Main Methods:

  • Utilized headspace equilibration technique with aqueous samples.
  • Employed a custom-built chamber connected to a portable gas analyzer.
  • Injected headspace gas subsamples into the analyzer via a closed-loop system.
  • Compared results with gas chromatography-flame ionization detection (GC-FID) for validation.

Main Results:

  • Achieved high correlation (r² > 0.98) between optical spectroscopy and GC-FID for methane (CH4) measurements.
  • Demonstrated the effectiveness of the portable analyzer for dissolved GHG quantification.
  • The developed chamber is suitable for samples requiring pre-injection dilution.

Conclusions:

  • The developed protocol offers a practical, cheaper, and more efficient alternative for measuring dissolved GHGs in aquatic systems.
  • This method is particularly valuable for field studies in remote locations lacking advanced laboratory equipment.
  • Enhances the capability of ecological studies to monitor GHG dynamics in aquatic environments.