Related Experiment Video
Updated: May 2, 2026

Full-root Aortic Valve Replacement by Stentless Aortic Xenografts in Patients with Small Aortic Roots
Published on: May 21, 2017
Early and severe aortic endograft infection after percutaneous coil embolization of type 2 endoleak: A case report
Quentin Balézeaux1, Aurélie Leroux1, Bruno Krug2
1Department of Cardio-Vascular, Thoracic Surgery and Lung Transplantation, CHU UcL Namur, UcLouvain, Yvoir, Belgium.
Introduction:
Endovascular aneurysm repair for abdominal aortic aneurysm is superior to open surgery regarding perioperative morbidity and mortality. Complications such as endoleaks represent a significant source of secondary intervention. Vascular graft infection is another serious complication found in 0.2 to 1 % of series. We hereby describe a case of a rapidly progressive aortic infection by Cutibacterium acnes following a percutaneous embolization procedure for a type II endoleak.
Case Presentation:
A 75-year-old man presented with a fever along with lower back and buttock pain five days after embolization via direct percutaneous puncture for a type II endoleak. White blood cell scintigraphy and blood culture suggested the presence of aortitis, but the patient experienced notable spontaneous improvement in both clinical symptoms and biological markers. The patient underwent CT-angiography which revealed aneurysm rupture requiring urgent open surgery and initiation of antimicrobial therapy. Similarly to blood cultures, per-operative aortic wall tissue samples also revealed presence of Cutibacterium acnes.
Discussion:
Aortic endograft infection after embolization is an uncommon complication. The diagnosis is based on a combination of imaging, blood, and nuclear tests. Repeated CT-angiography may be helpful when infection occurs quickly after embolization. Staphylococcus and Streptococci are common pathogens implicated in these infections.
Conclusions:
This is a case of an early and severe aortic endograft infection after percutaneous coil embolization of type 2 endoleak. Rupture occurred in less two weeks despite a slow-growing organism infection. The treatment includes endograft removal and antibacterial therapy. Caution is warranted when suspecting aortic endoprosthesis infection, necessitating close follow-up.
More Related Videos
09:32Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging
Published on: December 9, 2021
08:12Fully Endoscopic Mitral Valve Repair with Percutaneous Cannulation of Groin Vessels
Published on: May 26, 2023
Related Concept Videos
Aortic Regurgitation I: Introduction
Endocarditis I: Introduction
Endocarditis II: Clinical Features of Infective Endocarditis
Endocarditis III: Medical Management
Endocarditis IV: Nursing Management
Aneurysm III: Interprofessional Care