Related Experiment Video
Updated: Jun 16, 2025

In Vivo Quantitative Assessment of Myocardial Structure, Function, Perfusion and Viability Using Cardiac Micro-computed Tomography
Published on: February 16, 2016
The prognostic value of single photon emission computed tomography (SPECT) myocardial perfusion imaging is
Patrick Martineau1,2, Piotr Slomka3, Andrew L Goertzen4
1Department of Radiology, University of British Columbia, Vancouver, British Columbia, Canada.
Insights
Myocardial perfusion imaging (MPI) effectively predicts cardiac events regardless of left ventricular size. Stress total perfusion deficit (TPD) independently forecasts major adverse cardiac events (MACE), even in smaller hearts, confirming SPECT MPI
Area of Science:
- Cardiology
- Nuclear Cardiology
- Cardiac Imaging
Background:
- Myocardial perfusion imaging (MPI) accuracy can be influenced by various factors, with left ventricular (LV) size effects underexplored.
- Partial volume averaging in smaller hearts may obscure perfusion defects, potentially diminishing MPI's prognostic value.
- Understanding LV size impact is crucial for optimizing MPI interpretation and prognostic assessment.
Purpose of the Study:
- To investigate the influence of left ventricular size on the prognostic power of single photon emission computed tomography (SPECT) MPI.
- To determine if left ventricular end-diastolic volume affects the prediction of major adverse cardiac events (MACE) by stress total perfusion deficit (TPD).
Main Methods:
- SPECT MPI was performed on 2,503 patients without pathologically dilated LV.
- Stress total perfusion deficit (TPD) and rest end-diastolic volume (REDV) were quantified.
- Area under the curve (AUC) and Cox regression analyses assessed MACE prediction, stratified by sex and REDV tertile.
Main Results:
- Stress TPD demonstrated significant AUCs for MACE risk stratification across all sex and REDV tertiles (P<0.05).
- Increasing stress TPD, but not REDV, was independently associated with MACE in both men and women.
- No significant interaction between TPD and REDV was observed, indicating LV size did not modify TPD's prognostic impact.
Conclusions:
- The prognostic power of SPECT MPI, specifically stress TPD, is independent of left ventricular size.
- LV size does not appear to confound the prediction of MACE by SPECT MPI.
- These findings support the consistent utility of SPECT MPI for risk stratification across diverse patient populations.
Abstract:
Many variables have been shown to impact accuracy and prognostic power of myocardial perfusion imaging (MPI); however, effects of left ventricular size have not been extensively studied. In particular, perfusion defects in smaller hearts could be overlooked due to partial volume averaging, potentially reducing the prognostic power of MPI. We determined stress total perfusion deficit (TPD) and rest end diastolic volume (REDV) from single photon emission computed tomography (SPECT) MPI in consecutive patients without pathologically dilated left ventricles. Area under the curve (AUC) and Cox regression analysis were used to assess prediction of subsequent major adverse cardiac events [MACE-death, hospitalized acute myocardial infarction (AMI), hospitalized unstable angina, late revascularization]. Analyses were stratified by sex and REDV tertile. The analytic population included 2,503 patients (965 men and 1,538 women). Outcomes were assessed over an average of 6.4±2.3 years. MACE was observed in 254 (26.3%) of 965 men and 261 (17.0%) of 1,538 women. Stress TPD showed significant AUCs for stratifying MACE risk regardless of sex and REDV tertile (all P<0.05). In Cox regression analysis, increasing stress TPD (but not REDV) was associated with MACE in both men and women. There was no significant TPD*REDV interaction. In conclusion, we found the prognostic power of SPECT MPI to be independent of left ventricular size.
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...