Related Experiment Video
Updated: Jun 16, 2025

Rapid Point-of-Care Assay of Enoxaparin Anticoagulant Efficacy in Whole Blood
Published on: October 12, 2012
Plasma apixaban concentrations and thrombin generation assay parameters in response to dose reduction for atrial
Muhan Yeo1, So-Ryoung Lee1,2, Eue-Keun Choi1,2
1Department of Internal Medicine, Seoul National University College of Medicine, Seoul, Republic of Korea.
Aims:
To investigate plasma apixaban concentrations and thrombin generation assay (TGA) parameters across different apixaban doses in atrial fibrillation patients who had dose-reduction criteria for apixaban.
Methods:
This observational study included 374 patients (mean age 75.6 ± 7.7 years, 54.8% female) with dose-reduction criteria for apixaban. The patients were divided into 3 groups: (i) on-label standard dose (5 mg twice daily, n = 166); (ii) on-label reduced dose (2.5 mg twice daily, n = 55); and (iii) off-label underdose (2.5 mg twice daily, n = 153). Apixaban concentrations determined via the anti-Xa assay and TGA parameters were compared at trough levels.
Results:
The off-label underdose group exhibited significantly lower apixaban trough concentrations than the on-label reduced-dose and standard-dose groups (56.7 ± 42.9 vs. 83.7 ± 70.4 vs. 129.9 ± 101.8 ng/mL, all P < .001). Less than 70% of all patients fell within the expected range of apixaban concentrations. Proportions exceeding the upper limit of the expected range were significantly lower in the off-label underdose group (1.3%) than in the on-label reduced-dose (9.1%, P = .005) and standard-dose (12.7%, P < .001) groups. The TGA parameters showed the on-label standard-dose group displaying the lowest thrombogenic profiles. Lower creatinine clearance was the most significant predictor of higher apixaban concentrations.
Conclusion:
Off-label underdosed apixaban resulted in lower apixaban concentrations than both on-label standard and reduced-dose regimens. A considerable proportion of the patients exhibited apixaban concentrations outside the expected range, suggesting the potential benefits of plasma concentration monitoring. Further studies are needed to compare dosages directly, investigate the impact of plasma apixaban concentration monitoring and validate the current dose-reduction criteria.
Related Concept Videos
Anticoagulant Drugs: Low-Molecular-Weight Heparins
Anticoagulant Drugs: Vitamin K Antagonists and Direct Oral Anticoagulants
Warfarin, a prominent vitamin K antagonist family member, exerts its effect by inhibiting the enzyme VKORC1 (vitamin K epoxide reductase complex 1). By hindering this enzyme, warfarin...
Clot Retraction and Fibrinolysis
Renal Failure: Dose Adjustments
Reduced renal clearance and elimination rate are common outcomes of renal impairment. These alterations lead to a prolonged elimination half-life and an altered apparent volume of distribution for drugs. As a result, dosage adjustments are typically necessary to maintain optimal drug levels in the body.
However, dosage adjustments...
Time Course of Drug Effect
Drug Concentration Versus Time Correlation
Two pivotal parameters are the minimum effective concentration (MEC) and the minimum toxic concentration (MTC). The MEC is the...

