Stressing the Relevance of Differentiating between Systematic and Random Measurement Errors in Ultrasound Muscle
Lars Hubertus Lohmann1,2, Martin Hillebrecht3, Stephan Schiemann4
1University Sport Center, Carl von Ossietzky University Oldenburg, Oldenburg, Germany. lohmannlars@gmx.de.
Background:
The majority of studies that explore changes in musculature following resistance training interventions or examine atrophy due to immobilization or sarcopenia use ultrasound imaging. While most studies assume acceptable to excellent reliability, there seems to be unawareness of the existing absolute measurement errors. As early as 1998, methodological research addressed a collective unawareness of the random measurement error and its practical indications. Referring to available methodological approaches, within this work, we point out the limited value of focusing on relative, correlation-based reliability indices for the interpretability in scientific research but also for clinical application by assessing 1,512 muscle thickness values from more than 400 ultrasound images. To account for intra- and inter-day repeatability, data were collected on two consecutive days within four testing sessions. Commonly-stated reliability values (ICC, CV, SEM and MDC) were calculated, while evidence-based agreement analyses were applied to provide the accompanied systematic and random measurement error.
Results:
While ICCs in the range of 0.832 to 0.998 are in accordance with the available literature, the mean absolute percentage error ranges from 1.34 to 20.38% and the mean systematic bias from 0.78 to 4.01 mm (all p ≤ 0.013), depending on the measurement time points chosen for data processing.
Conclusions:
In accordance with prior literature, a more cautious interpretation of relative reliability values should be based on included systematic and random absolute measurement scattering. Lastly, this paper discusses the rationale for including different measurement error statistics when determining the validity of pre-post changes, thus, accounting for the certainty of evidence.
More Related Videos
Related Concept Videos
Random and Systematic Errors
Uncertainty in Measurement: Accuracy and Precision
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Systematic Error: Methodological and Sampling Errors
Sampling errors originate from improper sampling methods or the wrong sample population. These errors can be minimized by refining the sampling strategy. Defective instruments or faulty calibrations are the sources of instrumental...