Related Experiment Video
Updated: May 11, 2026

07:32
Balloon-based Injury to Induce Myointimal Hyperplasia in the Mouse Abdominal Aorta
Published on: February 7, 2018
9.6K
Outcomes of balloon-assisted maturation with large-diameter balloons
Amandeep Juneja1, David E Wang2, Litton Whitaker1
1Nuvance Health, Danbury, CT, USA.
The Journal of Vascular Access
|August 16, 2024
Summary
Using large angioplasty balloons for initial balloon-assisted maturation (BAM) of arteriovenous fistulas (AVF) significantly improves maturation rates and reduces the time to catheter-free hemodialysis (HD). This technique leads to better outcomes for AVF patients requiring dialysis.
Area of Science:
- Vascular Surgery
- Nephrology
- Interventional Radiology
Background:
- Arteriovenous Fistula (AVF) maturation is critical for successful hemodialysis (HD).
- Balloon-assisted maturation (BAM) is employed for inadequate AVF.
- Optimizing initial BAM techniques is essential for improving patient outcomes.
Purpose of the Study:
- To evaluate the effectiveness of initial BAM using large-diameter angioplasty balloons (≥7 mm).
- To compare outcomes between patients receiving large-diameter versus smaller-diameter (<7 mm) balloons for initial BAM.
- To assess the impact of balloon size on AVF maturation, complications, and time to catheter-free HD.
Main Methods:
- Retrospective review of patients undergoing BAM between 2018-2021.
- Comparison of outcomes between two groups: initial BAM with ≥7 mm balloons (Group I) and <7 mm balloons (Group II).
- Primary outcome: AVF maturation rate. Secondary outcomes: complications, re-intervention rates, vein diameter, and time to catheter-free HD.
Main Results:
- Group I (≥7 mm balloons) showed a significantly higher AVF maturation rate (97% vs. 88%, p=0.003).
- Larger initial vein diameter (5.9 mm vs. 5.1 mm, p=0.03) and reduced need for re-intervention were observed in Group I.
- Group I patients achieved catheter-free HD faster (29 days vs. 42 days, p=0.002) with higher 60-day incidence (83% vs. 67%, p=0.001).
Conclusions:
- Initial BAM with large-diameter angioplasty balloons is associated with superior AVF maturation rates.
- This approach leads to fewer re-interventions and a shorter time to achieving catheter-free hemodialysis.
- Favorable baseline characteristics often correlate with the successful use of larger balloons in BAM procedures.
Related Concept Videos
Bernoulli's Principle: Applications
There are many devices and situations in which fluid flows at a constant height and so can be analyzed using Bernoulli's principle. These devices include, but are not limited to, entrainment devices and fluid flow measuring devices.
Entrainment devices use a high fluid speed to create low pressures and, thus, entrain one fluid into another. Some examples of these devices are given below:
Entrainment devices use a high fluid speed to create low pressures and, thus, entrain one fluid into another. Some examples of these devices are given below:
Bioreactor Controls-II
In aerobic fermentations, oxygen is vital for microbial growth and metabolite production. Since air comprises only about 20% oxygen and the gas is poorly soluble in water—just 9 ppm at 20°C—supplying sufficient oxygen becomes a critical challenge, especially in high-demand processes like yeast growth or citric acid production. Even a fully saturated broth may offer only a few seconds of oxygen availability.To address this, sterile or scrubbed air is introduced into the fermentor via a sparger...