Related Experiment Video
Updated: Jun 16, 2025

Elemental-sensitive Detection of the Chemistry in Batteries through Soft X-ray Absorption Spectroscopy and Resonant Inelastic X-ray Scattering
Published on: April 17, 2018
Oxygen Substitution to Enhance Chemo-Mechanical Stability at the Cathode-Sulfide Electrolyte Interface in
Taesoon Hwang1, Jong-Hyuk Bae2, So-Ri Lee2
1Department of Materials Science and Engineering, University of Texas at Dallas, Richardson, Texas 75080-3021, United States.
Abstract:
The high interface resistance at the cathode-sulfide electrolyte interface is still a crucial drawback in an all-solid-state battery, unlike the initial expectation that the all-solid-state interface would enhance electrochemical stability by reducing side reactions at the interface. In this study, we examined the fundamental mechanism of unexpected reactions at the interface of LiNi0.8Co0.1Mn0.1O2 (NCM811) and argyrodite (Li6PS5Br0.5Cl0.5, LPSBC) sulfide solid electrolytes based on the combined method of multiscale simulations and electrochemical experiments. The high interface resistance originates from the formation of a passivating layer at the interface combined with irregular atomic and electronic structures, Li depletion, mutual element exchange, and mechanical contact loss between the oxide cathode and sulfide solid electrolyte. We also confirmed that these side reactions were suppressed by O substitutions to sulfide solid electrolyte (LPSOBC), and then the chemo-mechanical stability of the all-solid battery was enhanced by alleviating the side reactions at the interface. This study provides rational insights into the design of an interface for all-solid-state batteries.
Related Concept Videos
Batteries and Fuel Cells
Electrolysis
Voltaic/Galvanic Cells
Spontaneous redox reactions occur abundantly in nature. The chemical reaction occurring in a disposable AA battery powering our remote controls is one such example of a spontaneous redox reaction. Another example is the immersion of coiled copper wire into an aqueous silver nitrate solution. The reaction shows a gradual, visually impressive color change from colorless to bright blue and the formation of a grey precipitate on the copper wire. In this experiment,...
Formation of Complex Ions
Ladder Diagrams: Redox Equilibria
Consider the Fe3+/Fe2+ half-reaction, which has a standard-state potential of +0.771 V. At potentials more positive than +0.771 V, Fe3+ predominates, whereas Fe2+...
Standard Electrode Potentials

