Related Experiment Video
Updated: Jun 16, 2025

Bovine Mammary Gland Biopsy Techniques
Published on: December 23, 2018
Seasonal assessment of mastitis in crossbred goats: A thermographic approach
S L Gayathri1, M Bhakat1, T K Mohanty1
1Livestock Production Management Division, ICAR- National Dairy Research Institute, Karnal, Haryana, 132001, India.
Abstract:
Sub-clinical mastitis exhibits a higher prevalence in dairy goats than clinical mastitis, necessitating the adoption of non-invasive diagnostic techniques such as infrared thermography (IRT) to detect this economically significant production disease in the dairy sector. Accordingly, this study aims to employ IR imaging of the udder and teat quarters of lactating crossbred goats (Alpine × Beetal and Sanen × Beetal) across various seasons, utilising IRT, to discern cases of sub-clinical (SCM) and clinical mastitis (CM). Over a year, 100-110 lactating crossbred dairy goats underwent consistent IRT screenings, followed by a comprehensive evaluation of udder health status using the California mastitis test and somatic cell count (SCC). The receiver operating characteristic (ROC) analysis was conducted to establish the cut-off values for different thermographic parameters in this study. The results revealed that the SCC increased significantly (p < 0.01) in healthy, SCM, and CM milk samples across the seasons. The analysis of ROC revealed a comparatively higher sensitivity, specificity, and accuracy for udder thermograms during SCM than CM and vice versa for teat thermograms. IRT analysis reflected a difference (p < 0.01) in the udder and teat thermograms among quarters of healthy, SCM, and CM in summer, winter, autumn, and rainy seasons. A significant increase (p < 0.01) in udder thermograms was observed for quarters affected with SCM and CM relative to healthy, with an increase of 1.89 and 2.94 °C in winter, 0.85 and 1.63 °C in summer, 0.73 and 1.41 °C in rainy, and 1.33 and 2.38 °C in autumn, respectively. Similarly, for teat thermograms it was 1.79 and 2.81 °C in winter, 0.76 and 1.41 °C in summer, 0.70 and 1.37 °C in rainy, and 1.09 and 1.93 °C in autumn, respectively. Therefore, regardless of the seasons examined in this study, IRT proves to be an effective and supportive tool for early mastitis detection in lactating crossbred dairy goats.
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...

