A Coregistered Ultrasound and Photoacoustic Imaging Protocol for the Transvaginal Imaging of Ovarian Lesions
Published on: March 3, 2023
Diagnostic performance of ultrasound reporting systems in evaluation of adnexal masses: A prospective observational
Shagun Kapoor1, Seema Singhal1, Ekta Dhamija2
1Department of Obstetrics and Gynaecology, All India Institute of Medical Sciences, New Delhi 110029, India.
Objective(S):
To evaluate and compare diagnostic performance of ultrasound-based reporting systems IOTA SR, ADNEX, GIRADS, ORADS for discrimination between benign and malignant adnexal masses.
Study Design:
A prospective observational study in a tertiary care hospital's Obstetrics and Gynaecology department evaluated pre-operative ultrasound imaging for adnexal masses in 80 cases, comparing various reporting systems' sensitivity and specificity against histopathology as gold standard using STATA version 17.0 for data analysis.
Results:
Among the 80 masses, 55 % (44/80) were confirmed as benign on histopathology, while 45 % were identified as malignant. The sensitivity and specificity of SR was 100 % (95 %CI: 90.0-100) and 97.1 % (95 %CI: 84.7-99.9) respectively. Eleven masses (13.8 %) were inconclusive, reducing specificity to 75 % (95 %CI:59.7-86.8).In ADNEX optimal cut-off for risk of malignancy was 34.1 % with sensitivity of 86.1 % (95 % CI: 70.5-95.3) and specificity of 90.9 % (95 % CI: 78.3-97.5). Considering GIRADS 4-5 and risk threshold of ≥10 % (ORADS 4-5) as predictors of malignancy sensitivity was 100 % (95 %CI: 90.3-100) and specificity was 70.5 % (95 %CI: 54.8-83.2) for GIRADS and ORADS. All reporting systems were comparable (p = 0.7). ADNEX identified 72.7 % (8/11) of inconclusive cases, outperforming GIRADS/ORADS which correctly classified 27.2 % (3/11) cases. When applied to misclassified GIRADS/ORADS 4-5 category, ADNEX demonstrated superior performance by correctly classifying 76.9 % (10/13) masses, while SR achieved correct classification in only 38.5 % (5/13) masses.
Conclusion(S):
All classification systems showed comparable accuracy in malignancy risk identification on imaging. GIRADS/ORADS tended to overestimate malignancy risk. The present study recommends a two-step strategy, leveraging higher specificity of ADNEX model for improved stratification of adnexal masses.
More Related Videos
Related Concept Videos
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Ultrasound I: Abdominal Ultrasonography
Abdominal ultrasonography, commonly known as abdominal ultrasound, is a vital, non-invasive medical imaging technique widely used in healthcare.
Procedure:
This diagnostic tool allows the clinician to visually inspect internal structures within the abdomen, including vital organs such as the liver, gallbladder, pancreas, kidneys, and spleen.
The abdominal ultrasound process begins with applying a special gel to the patient's skin over the abdomen. This gel enhances the...
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Assessment of the Abdomen II: Percussion
Percussion
Percussion is an essential...