Related Experiment Video
Updated: Jun 16, 2025

Transcutaneous Microcirculatory Imaging in Preterm Neonates
Published on: December 31, 2015
Improvement of temperature surveillance of neonates in low-resource settings by a simple low-cost device: a
Janneke Garvs1, Orsolya Genzel-Boroviczény2, Ajib Phiri3
1Department of Pediatrics at Dr von Hauner Children's Hospital, LMU Hospital, Munchen, Germany.
Introduction:
Neonatal hypothermia in low-resource settings is prevalent and closely associated with high morbidity and mortality. We examined if an easy-to-read temperature detector device improves health outcomes.
Methods:
In a descriptive study, 1009 admissions to a neonatal ward in a tertiary care hospital in Lilongwe, Malawi, were analysed and divided into a baseline and a trial group. The data of 531 newborns with standard care (SC) before the trial were compared with 478 newborns during the implementation of the device (device care=DC). Staff and caregivers were trained on using the device and how to react in case of hypothermia. Data were collected from patient files, device documentation sheets, interviews and focus group discussions. Hypothermia was defined as a body temperature <36.5°C.
Results:
During the trial, body temperatures throughout the hospital stay were significantly more often obtained (p<0.0001). The median temperature measurements per newborn per day were 1.3 times with SC and 1.6 times with DC, and mild hypothermia was more frequently detected. Moderate hypothermia was avoided in the lightest weight group possibly contributing to significantly shorter hospital stays of surviving newborns (p=0.007). Many caregivers had difficulties using and interpreting the device correctly, and 47% of the reported colours did not match the registered temperatures. Contrary to the above, a questionnaire and focus group discussions with caregivers and health workers showed a high acceptance and the overall opinion that the device was beneficial.
Conclusion:
With more frequent temperature checks, infants with lower birth weight possibly benefited from implementing an easy-to-read continuous temperature indicator, but hypothermia rates remained high. Our data and experiences reveal structural, communicational and consistency/interpretation deficits. Although specifically designed for low-resource settings, the implementation of the device needs a well-working and structured environment, especially regarding staff and caregiver communication.
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Decreased Body Temperature
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...