Related Experiment Video
Updated: Jun 16, 2025

A Complete Method for Evaluating the Performance of Photocatalysts for the Degradation of Antibiotics in Environmental Remediation
Published on: October 6, 2022
Preparation and application of KCC-1@ZIF-8 for the solid extraction of tetracycline with high adsorption capacity
Zhang Jingru1,2, Chu Hongtao1, Chen Jiaqi3
1College of Chemistry and Chemical Engineering, Qiqihar University, Qiqihar 161006, China.
Abstract:
In this study, three different materials were prepared: dendritic fiber-type silica (KCC-1), zeolitic imidazolate framework-8 (ZIF-8), and a new composite material called KCC-1@ZIF-8. These materials were synthesized using microemulsion, stirring, and coating methods, respectively. The properties of the materials were characterized using various techniques such as transmission electron microscopy (TEM), scanning electron microscopy (SEM), Fourier transform infrared spectroscopy (FTIR), TGA and X-ray diffraction (XRD). The results showed that KCC-1@ZIF-8 exhibited a significant increase in the BET surface area and pore size compared to the individual components KCC-1 and ZIF-8. These improved properties of the composite material were beneficial for enhancing the adsorption capacity. The effects of initial concentrations, solution pH and reaction time on the adsorption capacity were investigated. The adsorption kinetics and isothermal data of ZIF-8 and KCC-1@ZIF-8 fitted well with pseudo-second-order and Langmuir isotherm models. The results of adsorption thermodynamics show that the adsorption process is spontaneous and endothermic. KCC-1@ZIF-8 exhibited a very high adsorption capacity (751.46 mg g-1) at an initial TC hydrochloride concentration of 80 mg L-1 in an aqueous solution at 301.15 K, and the value was higher than that of ZIF-8 (549.80 mg g-1) under the same conditions. KCC-1 exhibited a relatively lower capacity (37.860 mg g-1). Based on these findings, KCC-1@ZIF-8 was considered a promising adsorbent for the treatment of wastewater contaminated with TC hydrochloride. Additionally, the composite material, when combined with high-performance liquid chromatography (HPLC), could be used as a solid-phase extraction adsorbent for the adsorption of TC hydrochloride in animal foodstuff samples. The calibration curves showed a linear range of 20-500 μg L-1, and the recovery rate ranged from 85.216% to 90.717%. No one has made adsorbents with this new structure before, and KCC-1@ZIF-8 possessed excellent adsorption properties, which make it a potential candidate for environmental remediation and analytical applications involving TC hydrochloride.
More Related Videos
10:33Development of Inhibitors of Protein-protein Interactions through REPLACE: Application to the Design and Development Non-ATP Competitive CDK Inhibitors
Published on: October 26, 2015
06:02Determining the Thermodynamic and Kinetic Association of a DNA Aptamer and Tetracycline Using Isothermal Titration Calorimetry
Published on: August 23, 2022
Related Concept Videos
Extraction: Advanced Methods
Ion-Exchange Chromatography