Related Experiment Video
Updated: Jun 16, 2025

Determining and Controlling External Power Output During Regular Handrim Wheelchair Propulsion
Published on: February 5, 2020
Characterizing the Compressive Force at L5/S1 During Patient Transfer From Bed to Wheelchair
Seyoung Lee1, Kitaek Lim1, Woochol Joseph Choi1
1Department of Physical Therapy, Injury Prevention and Biomechanics Laboratory, Yonsei University, Wonju, South Korea.
The peak compressive forces at L5/S1 during patient transfers have been estimated. However, no study has considered the actual patient body weight that caregivers had to handle during transfers. We developed a simple kinematic model of lifting to address this limitation. Fifteen prospective health care providers transferred a 70-kg individual who mimicked a patient ("patient") from bed to wheelchair. Trials were acquired with the patient donning (weighted) and doffing (unweighted) a 5-kg weight belt. Trials were also acquired with and without knee assistance and a mechanical lift. During trials, kinematics and kinetics of transfers were recorded to estimate the peak compressive force at L5/S1 using static equilibrium equations. The peak compressive force was associated with the transfer method (P < .0005), and the compressive force was 68% lower in lift-assisted than manual transfer (2230 [SD = 433] N vs 6875 [SD = 2307] N). However, the peak compressive force was not associated with knee assistance, nor with a change in the patient body weight. Our results inform that mechanical loading exceeding the National Institute for Occupational Safety and Health safety criterion occurs during patient transfers, confirming a high risk of lower back injuries in caregivers. However, the risk can be mitigated with the use of a mechanical lift.
The peak compressive forces at L5/S1 during patient transfers have been estimated. However, no study has considered the actual patient body weight that caregivers had to handle during transfers. We developed a simple kinematic model of lifting to address this limitation. Fifteen prospective health care providers transferred a 70-kg individual who mimicked a patient ("patient") from bed to wheelchair. Trials were acquired with the patient donning (weighted) and doffing (unweighted) a 5-kg weight belt. Trials were also acquired with and without knee assistance and a mechanical lift. During trials, kinematics and kinetics of transfers were recorded to estimate the peak compressive force at L5/S1 using static equilibrium equations. The peak compressive force was associated with the transfer method (P < .0005), and the compressive force was 68% lower in lift-assisted than manual transfer (2230 [SD = 433] N vs 6875 [SD = 2307] N). However, the peak compressive force was not associated with knee assistance, nor with a change in the patient body weight. Our results inform that mechanical loading exceeding the National Institute for Occupational Safety and Health safety criterion occurs during patient transfers, confirming a high risk of lower back injuries in caregivers. However, the risk can be mitigated with the use of a mechanical lift.
More Related Videos
08:40Quantifying Arms and Legs Contributions during Repetitive Electrically-Assisted Sit-To-Stand Exercise in Paraplegics: A Pilot Study
Published on: November 11, 2022
08:24Sit-to-stand-and-walk from 120% Knee Height: A Novel Approach to Assess Dynamic Postural Control Independent of Lead-limb
Published on: August 30, 2016