Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

IR Spectrometers01:25

IR Spectrometers

1.1K
There are two main infrared (IR) spectrophotometers: dispersive IR spectrometers and Fourier transform infrared (FTIR) spectrometers. In a dispersive IR spectrometer, a beam of infrared radiation produced by a hot wire is divided into two parallel equal-intensity beams using mirrors. One beam passes through the sample, while another is a reference beam. The beams then move through the monochromator, which separates the radiations into a continuous spectrum of different frequencies. The...
1.1K
UV–Vis Spectrometers01:14

UV–Vis Spectrometers

1.3K
The absorbance of UV and visible (UV–visible) radiations is measured using a UV–visible spectrophotometer. Deuterium lamps, which emit UV radiation, and tungsten lamps, which produce radiation in the visible region, are used as light sources in UV–visible spectrophotometers. A monochromator or prism is used for diffraction grating, i.e., to split the incoming radiation into different wavelengths. A system of slits is used to focus the desired wavelength on the sample cell.
1.3K
Infrared (IR) Spectroscopy: Overview01:09

Infrared (IR) Spectroscopy: Overview

1.5K
When electromagnetic radiation passes through a material, atoms or molecules transition from a lower to a higher energy state by absorbing radiation corresponding to the energy difference between the two states. The absorption of infrared (IR) radiation causes transitions between vibrational energy levels in a molecule. Therefore, IR spectroscopy is a useful analytical tool for determining the molecular structure of molecules.
Different compounds display unique properties due to their...
1.5K
Raman Spectroscopy Instrumentation: Overview01:26

Raman Spectroscopy Instrumentation: Overview

308
A conventional Raman spectrophotometer includes a laser source, a sample holding system, a wavelength selector, and a detector.
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
308

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

MoS<sub>2</sub> Heterojunction-Based Gas Sensor Platform Enables Real-Time Detection of Sarin at Room Temperature via Strong Adsorption and Enhanced Charge Transfer.

ACS sensors·2026
Same author

The inflammatory state of tumor peripheral liver tissue affects hepatocellular carcinoma progression and prognosis.

Discover oncology·2026
Same author

A novel dynamic nomogram based on contrast-enhanced computed tomography radiomics for prediction of glypican-3-positive hepatocellular carcinoma.

Frontiers in oncology·2025
Same author

Lymphoplasmacytic lymphoma with IgG-λ and free λ light chain paraprotein: A case report.

Medicine·2025
Same author

Multiscale theoretical study of infrared spectroscopy for the thermal denaturation process of aprotinin.

Journal of molecular modeling·2025
Same author

Efficacy and prognosis of allogeneic hematopoietic stem cell transplantation in aggressive NK-cell leukemia: a meta-analysis.

Annals of hematology·2025

Related Experiment Video

Updated: Jun 16, 2025

Infrared Degenerate Four-wave Mixing with Upconversion Detection for Quantitative Gas Sensing
10:42

Infrared Degenerate Four-wave Mixing with Upconversion Detection for Quantitative Gas Sensing

Published on: March 22, 2019

6.2K

A Long Wave-Infrared Miniatured Quantum Dot Spectrometer.

Suhui Wang1, Yi Wang1, Tengxiao Guo1

  • 1State Key Laboratory of NBC Protection for Civilian, Beijing 102205, China.

Analytical Chemistry
|August 21, 2024
PubMed
Summary

Researchers developed a novel long-wave infrared (LWIR) quantum dot (QD) spectrometer using inkjet-printed HgSe QD filters. This cost-effective device achieves high spectral resolution for detecting chemical warfare agent simulants.

More Related Videos

Resonance Fluorescence of an InGaAs Quantum Dot in a Planar Cavity Using Orthogonal Excitation and Detection
12:57

Resonance Fluorescence of an InGaAs Quantum Dot in a Planar Cavity Using Orthogonal Excitation and Detection

Published on: October 13, 2017

9.2K
Quantitative Analysis of Vacuum Induction Melting by Laser-induced Breakdown Spectroscopy
03:49

Quantitative Analysis of Vacuum Induction Melting by Laser-induced Breakdown Spectroscopy

Published on: June 10, 2019

7.2K

Related Experiment Videos

Last Updated: Jun 16, 2025

Infrared Degenerate Four-wave Mixing with Upconversion Detection for Quantitative Gas Sensing
10:42

Infrared Degenerate Four-wave Mixing with Upconversion Detection for Quantitative Gas Sensing

Published on: March 22, 2019

6.2K
Resonance Fluorescence of an InGaAs Quantum Dot in a Planar Cavity Using Orthogonal Excitation and Detection
12:57

Resonance Fluorescence of an InGaAs Quantum Dot in a Planar Cavity Using Orthogonal Excitation and Detection

Published on: October 13, 2017

9.2K
Quantitative Analysis of Vacuum Induction Melting by Laser-induced Breakdown Spectroscopy
03:49

Quantitative Analysis of Vacuum Induction Melting by Laser-induced Breakdown Spectroscopy

Published on: June 10, 2019

7.2K

Area of Science:

  • Materials Science
  • Spectroscopy
  • Nanotechnology

Background:

  • Long-wave infrared (LWIR) spectroscopy is crucial for chemical detection.
  • Existing LWIR spectrometers are often bulky and expensive.
  • Quantum dots (QDs) offer tunable optical properties for advanced sensor applications.

Purpose of the Study:

  • To develop the first LWIR quantum dot spectrometer.
  • To demonstrate a novel fabrication method for LWIR QD filter arrays.
  • To achieve high spectral resolution for detecting chemical warfare agent simulants.

Main Methods:

  • Fabrication of a 255-element HgSe QD filter array using inkjet printing with optimized QD inks.
  • Integration of the QD filter array with an LWIR array detector.
  • Application of a compressive-sensing-based least-squares linear regression (CS-LS) algorithm for spectral reconstruction.

Main Results:

  • Successful construction of an LWIR QD spectrometer.
  • Achieved a spectral resolution of 5.4 cm⁻¹ over the 8–14 μm range.
  • Demonstrated detection of dimethyl methylphosphonate, a chemical warfare agent simulant.

Conclusions:

  • The developed LWIR QD spectrometer offers a low-cost and compact alternative to existing technologies.
  • Optimized QD purification and ligand modification enhanced device stability and performance.
  • This technology holds promise for smaller, more accurate target identification and scale-up QD applications.