Related Experiment Video For Artificial intelligence
Updated: Jun 16, 2025

Semiautomated Longitudinal Microcomputed Tomography-based Quantitative Structural Analysis of a Nude Rat Osteoporosis-related Vertebral Fracture Model
Published on: September 28, 2017
Diagnostic accuracy of chest X-ray and CT using artificial intelligence for osteoporosis: systematic review and
Norio Yamamoto1,2,3, Akihiro Shiroshita4,5, Ryota Kimura4,6
1Department of Epidemiology, Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, Okayama University, Okayama, Japan. norio-yamamoto@umin.ac.jp.
Introduction:
Artificial intelligence (AI)-based systems using chest images are potentially reliable for diagnosing osteoporosis.
Methods:
We performed a systematic review and meta-analysis to assess the diagnostic accuracy of chest X-ray and computed tomography (CT) scans using AI for osteoporosis in accordance with the diagnostic test accuracy guidelines. We included any type of study investigating the diagnostic accuracy of index test for osteoporosis. We searched MEDLINE, EMBASE, the Cochrane Central Register of Controlled Trials, and IEEE Xplore Digital Library on November 8, 2023. The main outcome measures were the sensitivity, specificity, and area under the receiver operating characteristic curve (AUC) for osteoporosis and osteopenia. We described forest plots for sensitivity, specificity, and AUC. The summary points were estimated from the bivariate random-effects models. We summarized the overall quality of evidence using the Grades of Recommendation, Assessment, Development, and Evaluation approach.
Results:
Nine studies with 11,369 participants were included in this review. The pooled sensitivity, specificity, and AUC of chest X-rays for the diagnosis of osteoporosis were 0.83 (95% confidence interval [CI] 0.75, 0.89), 0.76 (95% CI 0.71, 0.80), and 0.86 (95% CI 0.83, 0.89), respectively (certainty of the evidence, low). The pooled sensitivity and specificity of chest CT for the diagnosis of osteoporosis and osteopenia were 0.83 (95% CI 0.69, 0.92) and 0.70 (95% CI 0.61, 0.77), respectively (certainty of the evidence, low and very low).
Conclusions:
This review suggests that chest X-ray with AI has a high sensitivity for the diagnosis of osteoporosis, highlighting its potential for opportunistic screening. However, the risk of bias of patient selection in most studies were high. More research with adequate participants' selection criteria for screening tool will be needed in the future.
Related Concept Videos
Radiological Investigation I: X-ray and CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
X-ray Imaging
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...