Related Experiment Video
Updated: Jun 15, 2025

16:40
A New Single Chamber Implantable Defibrillator with Atrial Sensing: A Practical Demonstration of Sensing and Ease of Implantation
Published on: February 28, 2012
26.2K
The First Use of a Defibrillator on a U.S. Commercial Airline
Aerospace Medicine and Human Performance
|August 22, 2024
Abstract:
Use of onboard commercial airline defibrillators began in 1997. At first, it was met with resistance but is now present on all planes. The first in-flight resuscitation of a passenger occurred in 1998 and is described here.
Related Concept Videos
Disturbances in Heart Rhythm
922
Arrhythmia or dysrhythmia refers to an abnormal heart rhythm caused by a defect in the heart's conduction system. It can cause the heart to beat irregularly, too quickly, or too slowly, leading to symptoms like chest pain, shortness of breath, and fainting. Factors such as stress, caffeine, alcohol, nicotine, cocaine, certain drugs, congenital defects, diseases, and electrolyte abnormalities can trigger arrhythmias.
Arrhythmias are categorized by their speed, rhythm, and origin. A slow...
Arrhythmias are categorized by their speed, rhythm, and origin. A slow...
922
Acute Respiratory Failure-IV
132
Respiratory failure can manifest suddenly or gradually, characterized by a rapid decline in PaO2 and a rapid rise in PaCO2. This situation indicates a severe respiratory problem that may quickly become a life-threatening emergency. One of the early signs of hypoxemic Acute Respiratory Failure (ARF) is a change in mental status due to the brain's sensitivity to oxygen levels and changes in acid-base balance. Symptoms such as restlessness, confusion, and agitation suggest inadequate oxygen...
132
Acute Respiratory Failure-I
180
Acute respiratory failure is a condition characterized by the inability of the lungs to perform their primary function: gas exchange. This failure leads to insufficient oxygen levels (hypoxemia) in the blood, elevated carbon dioxide levels (hypercapnia), or both, causing critical impairment in organ function.
Definition: It is defined by specific criteria based on blood gas measurements. Hypoxemia happens when the partial pressure of oxygen (PaO2) falls below 60 mmHg. At the same time,...
Definition: It is defined by specific criteria based on blood gas measurements. Hypoxemia happens when the partial pressure of oxygen (PaO2) falls below 60 mmHg. At the same time,...
180
Acute Respiratory Failure-II
187
Type I Respiratory Failure, or hypoxemic respiratory failure, occurs when the partial pressure of oxygen (PaO2) in arterial blood falls below 60 mmHg while breathing room air without a corresponding increase in arterial carbon dioxide levels (PaCO2). This condition highlights a significant impairment in the lungs' capacity to oxygenate the blood.
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include:
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include:
187
Acute Respiratory Failure-V
126
The treatment for acute respiratory failure varies based on factors like the underlying cause, overall health, and severity. A collaborative healthcare team is essential for early detection, often through arterial blood gas analysis. Identifying the cause is the primary goal, with treatment strategies adjusted for ventilation/perfusion (V/Q) mismatch, shunting, or diffusion impairment.
Ensure that patients are monitored continuously for their response to therapy, including changes in...
Ensure that patients are monitored continuously for their response to therapy, including changes in...
126
Acute Respiratory Failure-III
165
Hypercapnic respiratory failure, also known as Type 2 or ventilatory respiratory failure, is a severe condition characterized by the body's inability to effectively remove carbon dioxide (CO2) from the bloodstream. It leads to an arterial CO2 pressure (PaCO2) exceeding 45 mmHg and a blood pH above 7.35. This situation indicates that the body's ventilatory demand, or the ventilation needed to maintain normal PaCO2 levels, surpasses its supply or the maximum gas flow achievable without...
165