Recurrent decompression sickness and late repermeabilization of patent foramen oval closure prosthesis: a diver's
Antoine Deney1, Olivier Lairez2, Mathieu Coulange3,4
1Department of Cardiology, Rangueil University Hospital, 1, Avenue Jean Poulhès, TSA 50032, 31059 Toulouse, France.
Background:
Decompression sickness (DCS) is a well-known risk associated with scuba diving, particularly in people with right-to-left shunt, such as patent foramen oval (PFO). Herein, we present a unique case of late PFO permeabilization after closure.
Case Summary:
A 26-year-old male diver was diagnosed with DCS following a dive at 36 m. He underwent PFO closure with a STARFLEX® prosthesis. Ten years later, the patient was presented with recurrent manifestations suggestive of DCS. The performed diagnostic work-up detects a permeabilization of the implanted prosthesis, and he was treated with a conservative approach.
Discussion:
This case highlights the challenges in the management of PFO in divers and raises concerns about the long-term efficiency of PFO closure and the impact of diving-related factors on prosthesis patency.
More Related Videos
Related Concept Videos
Pneumothorax-II
Clinical Manifestations:
Tracheostomy Decannulation
Description of the Procedure
Decannulation refers to the permanent removal of the tracheostomy tube, signaling the resolution of the condition that initially necessitated the tracheostomy. The process requires a well-coordinated interplay between...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...