Related Experiment Video For Benign breast tumor
Updated: Jun 15, 2025

The Application of 1% Methylene Blue Dye As a Single Technique in Breast Cancer Sentinel Node Biopsy
Published on: June 1, 2019
The application of methylene blue location technique in deep-seated benign breast tumor resection under endoscopy: a
Qinbo Wang1,2,3,4, Qingyu Yang1,4, Zongyan Li1,4
1Division of Breast Surgery, Department of General Surgery, the Sixth Affiliated Hospital, Sun Yat-sen University, Guangzhou, China.
Background:
Endoscopic curative excision of benign breast diseases (BBDs) can preserve the cosmetic appearance of the breast. However, endoscopic surgery is not feasible, and some challenges still need to be addressed. Traditional line marker localization methods cannot visualize tumors, and the exploration of deep tumors may lead to certain risks of accidental injury. This study aimed to investigate the value of the methylene blue location (MBL) technique in endoscopic resection of deep-seated benign breast tumors.
Methods:
A total of 217 patients with benign deep breast tumors admitted to the Sixth Affiliated Hospital of Sun Yat-sen University between November 2017 and June 2023 met the inclusion criteria. Among them, 107 patients underwent endoscopic resection with a MBL, in which methylene blue was injected to guide the tumor resection endoscopically, whereas 110 patients underwent endoscopic resection with a skin mark location (SML), in which the tumor was located by a marking line on the skin. We compared patient characteristics, surgery-related data, complications, and cosmetic outcomes between the two groups.
Results:
Endoscopic breast tumor resection was successfully performed in 217 patients, none of whom had undergone open surgery. The mean operation time was significantly different between the MBL and SML groups (45.70±12.508 and 49.59±10.997 min, respectively; P=0.008<0.05), and blood loss in the MBL group was significantly reduced compared with that in the SML group (11.07±5.665 and 13.83±7.918 mL, respectively; P=0.004<0.05). There were no significant differences in drainage volume, length of hospital stay, or postoperative complications between the MBL and SML groups (P>0.05). The postoperative cosmetic outcomes of the patients were noteworthy, with no statistically significant differences between the two groups.
Conclusions:
The methylene blue positioning technique is safe and effective for the endoscopic treatment of deep breast tumors. It shortens operation time, reduces surgical complications, and is worthy of clinical promotion.