Related Experiment Video
Updated: Jun 15, 2025

Physiology Lab Demonstration: Glomerular Filtration Rate in a Rat
Published on: July 26, 2015
Comparison of hemodialysis urea clearance using spent dialysate and Kt/Vurea equations
Priyanka Khatri1,2, Andrew Davenport3
1Fast and Chronic Programmes, Alexandra Hospital, Singapore, Singapore.
Introduction:
Dialysis adequacy is traditionally calculated from pre- and post-hemodialysis session serum urea concentrations and expressed as the urea reduction ratio, or Kt/Vurea. However, with increasing hemodiafiltration usage, we wished to determine whether there were any differences between standard Kt/Vurea equations and directly measured spent dialysate urea clearance.
Methods:
Urea clearance was measured from collected effluent dialysate and compared with various other methods of Kt/Vurea calculation, including change in total body urea from measuring pre- and post-total body water with bioimpedance and the Watson equation, by standard Kt/V equations, and online clearance measurements using effective ionic dialysance (OLC).
Results:
We compared urea clearance in 41 patients, 56.1% male, mean age 69.3 ± 12.6 years with 87.8% treated by hemodiafiltration. Reduction in total body urea was greater when estimating changes in total body urea, compared to measured dialysate losses of 58.4% (48.5-67.6) vs 71.6% (62.1-78), p < 0.01. Sessional urea clearance (Kt/Vurea) was greater using the online Solute-Solver program compared to OLC, median 1.45(1.13-1.75) vs 1.2 (0.93-1.4), and 2nd generation Kt/V equations 1.3 (1.02-1.66), p < 0.01, but not different from estimated total body urea clearance 1.36 (1.15-1.73) and dialysate clearance 1.36 (1.07-1.76). The mean bias compared to the Solute-Solver program was greatest with OLC (-0.25), compared to second-generation equations (-0.02), estimated total body clearance (-0.02) and measured dialysate clearance (-0.01).
Conclusion:
This study demonstrated that the result from equations estimating urea clearance indirectly from pre- and postblood samples from hemo- and hemodiafiltration treatments was highly correlated with direct measurements of dialysate urea clearance.
Related Concept Videos
One-Compartment Open Model: Urinary Excretion Data and Determination of k
Renal Drug Clearance: Comparison Between Renal Excretion Methods
Renal clearance is often associated with the renal glomerular filtration rate (GFR), which represents the rate at which plasma is filtered through the glomeruli in the kidney. When drug reabsorption is minimal and there is no active secretion, renal clearance is closely related to the...
Renal Drug Clearance: Overview
Renal clearance can be calculated using different methods. One approach is to divide the urinary drug excretion rate by the plasma drug concentration. This method directly measures renal clearance, indicating the kidneys' efficiency in...
Determination of Renal Drug Clearance: Graphical and Midpoint Methods
The graphical method involves plotting the rate of drug excretion in urine against the plasma drug concentration. By analyzing the graph, the clearance can be calculated and obtained. Drugs rapidly excreted by the kidneys exhibit a...
Renal Clearance
Renal clearance refers to the volume of plasma cleared of a specific substance, such as creatinine, per unit of time. To measure clearance, urine samples are collected over a 24-hour period during each bladder voiding, followed by a single blood sample at the...
Factors Affecting Renal Clearance: Renal Impairment
One condition associated with renal failure is uremia. Uremia is characterized by impaired glomerular filtration and fluid accumulation in the body. This condition hinders the renal clearance of drugs, resulting in drug accumulation and potential...