Multi-analyte Biochip MAB Based on All-solid-state Ion-selective Electrodes ASSISE for Physiological Research
Published on: April 18, 2013
An integrated bipolar electrode with shared cathode for dual-mode detection and imaging of CEA
Shumin Wang1, Tengkai Wang2, Zehua Wang3
1Department of Gastroenterology, Qilu Hospital of Shandong University, 107 Wenhuaxi Road, Jinan, Shandong, 250012, China; Cheeloo College of Medicine, Shandong University, No. 44 Wenhua West Road, Jinan, Shandong, 250012, China; Key Laboratory of Optic-electric Sensing and Analytical Chemistry for Life Science, Ministry of Education, College of Chemistry and Molecular Engineering, Qingdao University of Science and Technology, Qingdao, 266042, China.
Abstract:
In this paper, we designed a novel shared cathode bipolar electrode chip based on Ohm 's law and successfully constructed a dual-mode dual-signal biosensor platform (DD-cBPE). The device integrates ELISA, ECL, and ECL imaging to achieve highly sensitive detection and visual imaging of carcinoembryonic antigen (CEA). The unique circuit structure of the device not only realizes the dual signal detection of the target, but also breaks the traditional signal amplification concept. The total resistance of the system is reduced by series-parallel connection of BPE, and the total current in the circuit is increased. In addition, Au@NiCo2O4@MnO2 nanozyme activity probe was introduced into the common cathode to enhance the conductivity of the material. At the same time, due to the excellent peroxidase (POD) activity of NiCo2O4@MnO2, the decomposition of H2O2 was accelerated, so that more electrons flowed to the BPE anode, and finally the dual amplification of the ECL signal was realized. The device affects the current in the circuit by regulating the concentration of the co-reactant TPrA, thereby affecting the resistance of the system. Finally, different luminescent reagents emit light at the same potential and the luminous efficiency is similar. In addition, the chip does not need external resistance regulation, which improves the sensitivity of the immunosensor and meets the needs of timely detection. It provides a new idea for the deviceization of bipolar electrodes and has broad application prospects in biosensors, clinical detection, and environmental monitoring.
More Related Videos
10:30Simultaneously Capturing Real-time Images in Two Emission Channels Using a Dual Camera Emission Splitting System: Applications to Cell Adhesion
Published on: September 4, 2013
07:25Author Spotlight: An Innovative Approach to Neural Electrical Stimulation Using Calcium Imaging
Published on: August 18, 2023
Related Concept Videos
¹³C NMR: ¹H–¹³C Decoupling
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...
Mass Analyzers: Common Types
Tandem Mass Spectrometry
Capillary Electrophoresis: Instrumentation
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
Double Resonance Techniques: Overview
Spin decoupling is usually achieved by...