Related Experiment Video
Updated: Jun 15, 2025

The Portable Chemical Sterilizer PCS, D-FENS, and D-FEND ALL: Novel Chlorine Dioxide Decontamination Technologies for the Military
Published on: June 29, 2014
Fomite disinfection using spray systems: A computational multi-physics framework
Pouria Arabi1, Hamid Montazeri2, Mahmood Yaghoubi1
1Shiraz University, Shiraz 71936-16548, Iran.
Abstract:
Disinfecting inanimate objects or materials carrying infectious agents, i.e., fomites, using spray systems reduces healthcare-associated infections in medical settings and community-acquired infections in non-medical environments. However, an accurate prediction of such systems is challenging as these systems embrace multi-physics phenomena depending on several parameters. Therefore, this paper presents a computational modeling-based multi-physics framework to evaluate the performance and effectiveness of spray systems employed in disinfecting fomites with non-porous hydrophilic surfaces. The framework includes four key phases: (i) atomizing the liquid disinfectant jet into the disinfectant droplets; (ii) interactions between disinfectant droplets and the surrounding air; (iii) impingements created by the disinfectant droplets on the fomite surface; (iv) interactions between the disinfectant depositions and pathogens causing fomite disinfection. The accuracy of the framework is evaluated using two sets of experimental data on the reduction of viable Bacillus atrophaeus spores over an 1800-second period. The results show that the framework can predict fomite disinfection via spray systems, with the deviations from the measured data being 2.73% and 2.38%. By presenting a detailed perception of the dynamics involved in fomite disinfection, this framework has the potential to improve public health practices and lead to the development of more effective and targeted disinfection strategies in diverse settings.
Related Concept Videos
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...